Related Experiment Video
Updated: Jan 14, 2026

Evaluation of Drug Sorption to PVC- and Non-PVC-based Tubes in Administration Sets Using a Pump
Published on: March 11, 2017
A novel approach for evaluating the containment of a closed intravenous administration system for hazardous drugs
Elana A Slutsky Smith1, Asaf Alon1
1Simplivia Healthcare Ltd, Kiryat Shmona, Israel.
Abstract:
Oncology nurses are routinely exposed to antineoplastic agents through skin absorption or inhalation of airborne agents when administering drugs intravenously. Although safe infusion devices aimed at preventing the hazardous disconnection of empty bags were developed, none of them are completely closed systems per National Institute for Occupational Safety and Health (NIOSH) guidelines. The authors evaluated a closed system administration device developed to prevent exposure of healthcare professionals to cytotoxic drugs during their administration. System components were assembled in various scenarios mimicking intravenous drug administration and then tested in a sealed chamber connected to a gas analyzer. The concentration of 70% isopropanol vapors (as a drug surrogate) was measured continuously in the chamber. The analysis showed no detectable increase in isopropanol vapor concentration in the sealed chamber compared to baseline levels over the course of the tasks, indicating that no leaks of 70% isopropanol occurred when the closed system administration devices were used. Furthermore, the results remained the same regardless of the number of connection cycles the products had undergone, or whether they were newly manufactured or at the simulated end of their shelf-life. This study showed that the use of a closed administration system can minimize the risk of exposure of healthcare professionals to hazardous drugs and potentially reduce environmental contamination.
More Related Videos
Related Concept Videos
Prevention of Further Absorption of Poison
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Drug Delivery: Parenteral Route
There are three primary parenteral routes: intravenous (IV), intramuscular (IM), and subcutaneous (SC). The IV route introduces the drug directly into the bloodstream, ensuring immediate action. The IM route...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...

