Car seat tolerance screen failure in the neonatal intensive care unit: clinical, oxygen saturation and heart rate

Britney He1, Paige Howard1, Sherry Kausch2

  • 1School of Medicine, University of Virginia, Charlottesville, VA, USA.

Pediatric Research
|October 28, 2025
PubMed

Insights

Infants failing car seat tolerance screens (CSTS) experienced more desaturations prior. Most premature infants passed a repeat screen shortly after, indicating successful adaptation.

Area of Science:

  • Neonatal care
  • Pediatric safety
  • Cardiorespiratory monitoring

Background:

  • American Academy of Pediatrics (AAP) guidelines recommend car seat tolerance screening (CSTS) for high-risk infants before hospital discharge.
  • Understanding factors associated with CSTS failure is crucial for refining screening protocols.

Purpose of the Study:

  • To compare clinical, oxygen saturation (SpO₂), and heart rate (HR) characteristics between infants who passed and failed their initial CSTS.
  • To identify predictors of CSTS failure in a neonatal intensive care unit (NICU) population.

Main Methods:

  • Retrospective analysis of 2861 CSTSs from 2523 infants at a single Level IV NICU (2018-2024).
  • Comparison of clinical data between infants who passed versus failed their first CSTS.
  • Analysis of SpO₂ and HR data, including hypoxemia and bradycardia events, for a subset of infants before and during CSTS.

Main Results:

  • First-time CSTS failure occurred in 4.4% of infants, primarily due to oxygen desaturation (85%).
  • Infants who failed their initial CSTS exhibited more desaturation events in the 24 hours preceding the screen and experienced deeper, longer desaturations during the test.
  • 77% of infants who failed their first CSTS passed a subsequent screen within an average of 1.9 days, with no significant difference in overall length of stay.

Conclusions:

  • CSTS failure in high-risk infants is linked to increased pre-screening oxygen desaturations.
  • Most infants who initially fail CSTS successfully pass a repeat screen within a short period.
  • Continuous physiologic monitoring during CSTS reveals significant differences in desaturation severity between infants who pass and fail.
Abstract

Related Concept Videos

Special considerations while measuring oxygen saturation01:19

Special considerations while measuring oxygen saturation

Assessing respiratory rate concurrently with pulse measurement is fundamental to patient care, providing valuable insights into the patient's respiratory function. The normal breathing rate for an adult usually falls within a normal range of 12 to 20 breaths per minute. Abnormal respiratory rates can signal underlying health conditions or the need for immediate intervention.
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
891
Oxygen Delivering System I: Nasal Cannula and Face Mask01:26

Oxygen Delivering System I: Nasal Cannula and Face Mask

The human body requires oxygen to function, and when the natural process of respiration is hindered, external devices, including the following, are needed to help deliver this vital gas.
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
1.4K
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen01:16

Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen

Oxygen therapy is a pivotal aspect of medical care, particularly for patients with respiratory ailments. Two prominent oxygen-delivering systems include the Venturi mask and the transtracheal oxygen catheter.
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
1.8K
Pulse Oximetry01:24

Pulse Oximetry

Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
1.2K
Respiratory Assessment: Purpose and Indications01:19

Respiratory Assessment: Purpose and Indications

Respiratory assessment is a cornerstone of nursing assessments, crucial for the early detection of patient deterioration. This evaluation transcends routine procedures, representing a critical skill nurses must master to ensure optimal patient care.
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
1.7K
Assessment of Ventilation I: Respiratory Rate01:20

Assessment of Ventilation I: Respiratory Rate

Assessment of Ventilation
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: