Analyzing Cardiorespiratory Motion and Its Dosimetric Effect on Stereotactic Arrhythmia Radio-Ablation: A
Luuk H G van der Pol1, Stefano Mandija1, Brian V Balgobind2
1Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands.
Purpose:
Stereotactic arrhythmia radio-ablation (STAR) is increasingly used to treat refractory ventricular tachycardia. The importance of cardiorespiratory motion during STAR is still poorly understood. We collected multicenter STOPSTORM.eu data to estimate cardiorespiratory motion and its dosimetric impact on STAR-deliveries.
Methods And Materials:
Data were collected from 61 ventricular tachycardia patients. Treatments were performed in free-breathing (FB) with an internal-target volume (FB:ITV) (25 patients), in FB with respiratory beam tracking (FB:TR) (11 patients), using abdominal compression (AC) (10 patients), or in deep inspiration breath-hold (BH) (15 patients). Reference computed tomography images were registered to all breathing/cardiac phases, and the resulting deformation vector fields were used to extract motion for target structures and auto-contoured cardiorespiratory structures (CSs). Additionally, CS were auto-contoured on all breathing/cardiac phases to extract motion independently. Inverse deformation vector fields were used to accumulate motion-adjusted dose distributions. Dose differences were estimated using the conformity index: (VPTV25Gy)2/(VPTV · V25Gy), for planning target volume, and maximum and mean dose differences for CS.
Results:
The median 95th percentile planning target volume motion was comparable between patients, with 6.0 mm (FB), 5.6 mm (AC), and 4.9 mm (BH). The left ventricle had the highest median 95th percentile motion out of all CS, with 6.8 mm (FB), 5.5 mm (AC), and 5.9 mm (BH). Estimated motion values were comparable between deformable image registration and auto-contouring (FB, 2.9-7.6 vs 3.1-8.5 mm; AC, 2.4-15.1 vs 3.0-9.0 mm; BH, 1.0-7.3 vs 2.4-6.7 mm). Median conformity index was reduced in the accumulated dose compared to the planned dose by: FB:ITV (-7.2%), AC (-14.1%), BH (-4.3%), and FB:TR (-1.3%). Mean CS dose increased by up to 2 Gy, and maximum dose increased by up to 1.2 Gy (excluding outliers). The largest dose differences were found for small CS.
Conclusions:
Motion and its dosimetric effect have similar magnitudes between treatment setups. Motion findings were consistent between deformable image registration and auto-contouring. Only tracking significantly limited the dosimetric impact of motion.
Related Concept Videos
Pathophysiology of Cardiac Performance
Heart Failure Drugs: β-Blockers
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...