Automatic Removal of Physiological Artifacts in OPM-MEG: A Framework of Channel Attention Mechanism Based on Magnetic
Yong Li1,2, Dawei Wang3, Hao Lu1,2
1Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 37 Xueyuan Rd., Haidian District, Beijing 100083, China.
Abstract:
The high spatiotemporal resolution of optically pumped magnetometers (OPMs) makes them an essential tool for functional brain imaging, enabling accurate recordings of neuronal activity. However, physiological signals such as eye blinks and cardiac activity overlap with neural magnetic signals in the frequency domain, resulting in contamination and creating challenges for the observation of brain activity and the study of neurological disorders. To address this problem, an automatic physiological artifact removal method based on OPM magnetic reference signals and a channel attention mechanism is proposed. The randomized dependence coefficient (RDC) is employed to evaluate the correlation between independent components and reference signals, enabling reliable recognition of artifact components and the construction of training and testing datasets. A channel attention mechanism is subsequently introduced, which fuses features from global average pooling (GAP) and global max pooling (GMP) layers through convolution to establish a data-driven automatic recognition model. The backbone network is further optimized to enhance performance. Experimental results demonstrate a strong correlation between the magnetic reference signals and artifact components, confirming the reliability of magnetic signals as artifact references for OPM-MEG. The proposed model achieves an artifact recognition accuracy of 98.52% and a macro-average score of 98.15%. After artifact removal, both the event-related field (ERF) responses and the signal-to-noise ratio (SNR) are significantly improved. Leveraging the flexible and modular characteristics of OPM-MEG, this study introduces an artifact recognition framework that integrates magnetic reference signals with an attention mechanism. This approach enables highly accurate automatic recognition and removal of OPM-MEG artifacts, paving the way for real-time, automated data analysis in both scientific research and clinical applications.
More Related Videos
08:45Mapping Cortical Dynamics Using Simultaneous MEG/EEG and Anatomically-constrained Minimum-norm Estimates: an Auditory Attention Example
Published on: October 24, 2012
09:25Detecting Pre-Stimulus Source-Level Effects on Object Perception with Magnetoencephalography
Published on: July 26, 2019
