Influence of the Catecholamine Syringe Changeover Method on Patients' Blood Pressure Variability: A Single-Center
Yuta Niitsu1, Takumi Tsuchida2, Ryuta Sato1
1Critical Care Nurse Center, Hokkaido University Hospital, Sapporo 060-8648, Japan.
Nursing Reports (Pavia, Italy)
|October 28, 2025
Summary
The catecholamine syringe exchange method does not significantly impact blood pressure variability in ICU patients. Age is a risk factor for blood pressure variability during catecholamine syringe exchange.
Area of Science:
- Critical Care Medicine
- Pharmacology
- Hemodynamics
Background:
- Limited evidence exists on catecholamine syringe exchange methods in Japan.
- Practices for catecholamine administration vary across healthcare facilities.
- Blood pressure variability is a critical concern in intensive care unit (ICU) patients.
Purpose of the Study:
- To investigate the effect of different catecholamine syringe exchange methods on blood pressure variability.
- To compare the double-pumping changeover (DPC) and quick syringe changeover (QC) methods.
- To identify factors influencing blood pressure variability during catecholamine administration in ICU patients.
Main Methods:
- Retrospective analysis of 119 ICU patients undergoing 308 catecholamine syringe exchanges.
- Propensity score matching to compare DPC and QC groups.
- Sub-analysis of patients with severe shock (systolic blood pressure ≤ 90 mmHg).
- Logistic regression to identify risk factors for blood pressure variability.
Main Results:
- No significant differences in blood pressure variability (coefficient of variation, absolute pressures) were observed between DPC and QC methods.
- Age was identified as the sole significant risk factor for increased blood pressure variability (OR: 1.018).
- Catecholamine syringe exchange methods did not significantly contribute to circulating blood pressure variability (OR: 1.186).
Conclusions:
- The choice between DPC and QC methods for catecholamine syringe exchange does not significantly affect blood pressure variability.
- Older adult patients may be more susceptible to blood pressure fluctuations during catecholamine syringe exchange.
- Further research may be needed to optimize catecholamine administration protocols for vulnerable patient populations.
More Related Videos
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
1.5K
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
1.5K
Special considerations while measuring blood pressure
1.2K
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
1.2K
Errors occurring during blood pressure monitoring
1.3K
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
1.3K
Assessment of blood pressure in brachial artery(one-step method)
1.1K
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
1.1K
Disorders of the Autonomic Nervous System
1.4K
The autonomic nervous system (ANS) is an intricate network of nerves that controls functions such as the regulation of heart rate, digestion, and blood pressure regulation. When this system malfunctions, it can lead to various disorders that affect multiple bodily functions. One common feature of many autonomic disorders is the involvement of smooth blood vessels, which play a crucial role in regulating blood flow throughout the body.
Raynaud's disease, also known as Raynaud's...
Raynaud's disease, also known as Raynaud's...
1.4K
Pre-Procedural Guidelines for Assessing Blood Pressure
807
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
807