Influence of the Catecholamine Syringe Changeover Method on Patients' Blood Pressure Variability: A Single-Center
Yuta Niitsu1, Takumi Tsuchida2, Ryuta Sato1
1Critical Care Nurse Center, Hokkaido University Hospital, Sapporo 060-8648, Japan.
Abstract:
Background/Objectives: In Japan, evidence on catecholamine syringe exchange methods is limited, with practices varying across facilities and individuals. In this study, we aimed to determine the effect of the catecholamine syringe exchange method on blood pressure variability in intensive care unit patients. Methods: We retrospectively analyzed 119 patients (308 syringe exchanges) who underwent catecholamine syringe exchange between 1 April 2020 and 31 March 2022. Patient characteristics for the double-pumping changeover (DPC) and quick syringe changeover (QC) groups were matched and compared using propensity scores. A sub-analysis focused on patients with severe shock with systolic blood pressures ≤ 90 mmHg. Logistic regression analysis was used to examine factors influencing blood pressure variability during the catecholamine syringe changeover. Results: Neither propensity score matching nor the sub-analysis for patients with shock revealed significant differences in the coefficient of variation or absolute systolic/diastolic/mean blood pressure within 15 min of syringe exchange in the two groups. Logistic regression revealed that age was the sole risk factor affecting blood pressure variability during syringe changeover (odds ratio: 1.018, 95% confidence interval: 1.001-1.036), while syringe changeover methods did not contribute to circulating variability (odds ratio: 1.186, 95% confidence interval: 0.672-2.092). Conclusions: Differences between the DPC and QC methods did not significantly affect blood pressure variability during catecholamine syringe changeovers. However, in older adult patients, catecholamine syringe changeover may be more likely to cause blood pressure variability.
More Related Videos
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Disorders of the Autonomic Nervous System
Raynaud's disease, also known as Raynaud's...
Pre-Procedural Guidelines for Assessing Blood Pressure