Evaluation of MRI-Based Measurements for Patellar Dislocation: Reliability and Reproducibility
Ivan Brumini1,2,3, Tamara Pranjkovic4, Danijela Veljkovic Vujaklija1,3
1Department of Diagnostic and Interventional Radiology, Clinical Hospital Center Rijeka, 51000 Rijeka, Croatia.
Diagnostics (Basel, Switzerland)
|October 29, 2025
Summary
Lateral trochlear inclination (LTI) and patellar tendon-lateral trochlear ridge distance (PT-LTR) are reliable MRI measurements for diagnosing patellar dislocation. These parameters show high diagnostic performance and reproducibility, aiding clinical assessment.
Area of Science:
- Orthopedics
- Radiology
- Biomedical Engineering
Background:
- Patellar dislocation is a common orthopedic injury.
- Accurate imaging assessment is crucial for diagnosis and management.
- Identifying reliable MRI measurements can improve diagnostic accuracy.
Purpose of the Study:
- To identify the most reliable magnetic resonance imaging (MRI) measurements for diagnosing patellar dislocation.
- To evaluate the diagnostic performance and inter-rater reliability of various MRI parameters.
Main Methods:
- Retrospective analysis of MRI scans from 86 knees (48 controls, 38 with patellar dislocation history).
- Measured parameters included lateral trochlear inclination (LTI), sulcus angle (SA), trochlear depth (TD), tibial tubercle-trochlear groove distance (TT-TG), and patellar tendon-lateral trochlear ridge distance (PT-LTR) and its novel modification (PT-LTR horizontal).
- Inter-rater reliability assessed using intraclass correlation coefficients (ICCs); diagnostic accuracy evaluated using ROC analysis.
Main Results:
- All measured parameters differed significantly between control and patient groups (p < 0.05).
- LTI demonstrated the highest diagnostic performance (AUC = 0.981) with excellent inter-rater agreement (sensitivity 89.5%, specificity 97.9%).
- PT-LTR and PT-LTR horizontal also showed strong diagnostic utility (AUC = 0.896) with good reliability.
Conclusions:
- LTI and PT-LTR (including modified versions) are reliable and reproducible MRI measurements for assessing patellar dislocation.
- These parameters offer high diagnostic performance and may be valuable tools in clinical imaging.
- Further prospective studies are recommended to validate their utility in diverse patient populations.