Related Experiment Video
Updated: Jan 13, 2026

Species Determination and Quantitation in Mixtures Using MRM Mass Spectrometry of Peptides Applied to Meat Authentication
Published on: September 20, 2016
Authentication of Maltese Pork Meat Unveiling Insights Through ATR-FTIR and Chemometric Analysis
Frederick Lia1, Mark Caffari2, Malcom Borg3
1BKEA BioKimika Extrakta Analytika Ltd., RBT 3140 Rabat, Malta.
Abstract:
Ensuring the authenticity of meat products is a critical issue for consumer protection, regulatory compliance, and the integrity of local food systems. In this study, attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy combined with chemometric and machine learning models was applied to differentiate Maltese from non-Maltese pork. Spectral datasets were subjected to a range of preprocessing techniques, including Savitzky-Golay first and second derivatives, detrending, orthogonal signal correction (OSC), and standard normal variate (SNV). Linear methods such as principal component analysis-linear discriminant analysis (PCA-LDA), the soft independent modeling of class analogy (SIMCA), and partial least squares regression (PLSR) were compared against nonlinear approaches, namely support vector machine regression (SVMR) and artificial neural networks (ANNs). The results revealed that derivative preprocessing consistently enhanced spectral resolution and model robustness, with the fingerprint region (1800-600 cm-1) yielding the highest discriminative power. While PCA-LDA, SIMCA, and PLSR achieved high accuracy, SVMR and ANN models provided a superior predictive performance, with accuracies exceeding 0.99 and lower misclassification rates under external validation. These findings highlight the potential of FTIR spectroscopy combined with nonlinear chemometrics as a rapid, non-destructive, and cost-effective strategy for meat authentication, supporting both consumer safety and sustainable food supply chains.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
09:18Profiling the Triacylglyceride Contents in Bat Integumentary Lipids by Preparative Thin Layer Chromatography and MALDI-TOF Mass Spectrometry
Published on: September 5, 2013
Related Concept Videos
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Matrix-Assisted Laser Desorption Ionization (MALDI)
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...