Data Acquisition Protocol for Determining Embedded Sensitivity Functions
Published on: April 20, 2016
Thermal Sensitivity of a Microoptoelectromechanical Evanescent-Coupling-Based Accelerometer
Evgenii Barbin1,2, Ivan Kulinich1, Tamara Nesterenko1,3
1Research Institute of Microelectronic Systems, The Tomsk State University of Control Systems and Radioelectronics, 634050 Tomsk, Russia.
Abstract:
This treatise studies the thermal sensitivity of the mechanical and optical transmission coefficients of a microoptoelectromechanical (MOEM) accelerometer based on evanescent coupling in a temperature range from minus 40 to plus 125 °C. Two types of optical measuring transducers are considered: based on a directional coupler and a resonator. This analysis covers the optical and mechanical components of the thermal sensitivity of the transmission coefficient. In terms of the mechanical part, the temperature effect induces changes to the linear dimensions of the structure and material characteristics and causes internal mechanical stresses as well. The temperature effect on the optical system of the accelerometer is conditioned by the thermo-optic effect of the materials the optical waveguides are made of. This study includes experiments on the refraction index dependence on the temperature of the optical films that compose the optical system of the MOEM accelerometer. The experiment shows that the refraction index of the films grows with temperature and amounts to 0.12642 ppm/°C for silicon nitride on the SiO2/Si substrate. For the optical measuring transducer based on a directional coupler, the thermal sensitivity of the accelerometer's optical transmission coefficient is 580 ppm/°C. For the resonator-based transducer, the thermal sensitivity is 0.33 °C-1. The thermal sensitivity of the normalized mechanical transmission coefficient of the accelerometer is 120 ppm/°C. For optical measuring transducers based on a directional coupler, the contribution of the temperature dependent refraction index alteration to the overall error is 5 times larger than that of the MOEM accelerometer's mechanical parameters, while for the resonator-based transducer the difference reaches 3000 times. This means its operability is only possible in a thermostatic environment.
More Related Videos
Related Concept Videos
Measuring Acceleration Due to Gravity
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...