Validation of a direct injection-GC-MS method for the quantification of volatile alcohols in blood and vitreous humor

Lokmane Dali Braham1, Abderrahmane Kori Yahia2, Feriel Hadji2

  • 1Department of Forensic medicine, Mustapha Pasha University Hospital, Algiers, Algeria. lokmane.dali.braham@gmail.com.

Related Concept Videos

Volatilization01:10

Volatilization

Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
4.7K
Mass Spectrometry: Alcohol Fragmentation01:03

Mass Spectrometry: Alcohol Fragmentation

Alcohols (R-OH) ionize to lose one non-bonded electron from the oxygen atom, forming molecular ions. Due to their tendency to fragment rapidly, the intensity of the molecular ion peak in the mass spectrum is weak or sometimes absent. The fragmentation patterns for alcohols occur in two ways, i.e. ⍺-cleavage and dehydration. During ⍺-cleavage, the bond at the ⍺-position adjacent to the hydroxyl group cleaves to give a resonance-stabilized cation and a radical. However, intramolecular...
4.4K
Gas Chromatography: Sample Injection Systems01:08

Gas Chromatography: Sample Injection Systems

In gas chromatography, the sample is introduced as a vapor plug into the carrier gas stream for high efficiency and resolution. A microsyringe injects the sample solution into a heated sample port, vaporizing it and mixing it with the carrier gas. This process is important to ensure the sample is properly prepared for analysis. Thermally sensitive samples can be injected directly into the column and volatilized by slowly increasing the column temperature.
Two primary injection methods are used...
1.3K
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
6.5K
IR and UV–Vis Spectroscopy of Aldehydes and Ketones01:29

IR and UV–Vis Spectroscopy of Aldehydes and Ketones

Infrared spectroscopy, also known as vibrational spectroscopy, is mainly used to determine the types of bonds and functional groups in molecules. In aldehydes and ketones, the carbonyl (C=O) bond shows an absorption around 1710 cm-1. The C=O bond vibration of an aldehyde occurs at lower frequencies than that of a ketone. In addition to the C=O absorption in an aldehyde, the aldehydic C–H bond also gives two peaks in the 2700–2800 cm-1 range. This absorption, coupled with the...
7.3K