Detecting Laterality Errors in Combined Radiographic Studies by Enhancing the Traditional Approach With GPT-4o:
Kung-Hsun Weng1, Yi-Chen Chou1, Yu-Ting Kuo1,2,3
1Department of Medical Imaging, Chi Mei Medical Center, Tainan, Taiwan.
Background:
Laterality errors in radiology reports can endanger patient safety. Effective methods for screening for laterality errors in combined radiographic reports, which combine multiple studies into one, remain unexplored.
Objective:
First, we define and analyze the unstudied combined radiographic report format and its challenges. Second, we introduce a clinically deployable ensemble method (rule-based+GPT-4o), evaluated on large-scale, real-world, imbalanced data. Third, we demonstrate significant performance gaps between real-world imbalanced and synthetic balanced datasets, highlighting limitations of the benchmarking methodology commonly used in current studies.
Methods:
This retrospective study analyzed deidentified English radiology reports containing laterality terms in order. We split the data into TrainVal (combined training and validation dataset), Test-1 (both real-world, imbalanced), and Test-2 (synthetic, balanced). Test-1 comes from a distinct branch. Experiment 1 compared the baseline, workaround, and GPT-4o-augmented rule-based methods. Experiment 2 compared the rule-based method with the highest recall to fine-tuned RoBERTa, ClinicalBERT, and GPT-4o models.
Results:
As of July 2024, our dataset included 10,000 real-world and 889 synthetic radiology reports. The laterality error rate in real-world reports was 1.20% (120/10,000), significantly higher in combined (103/7000, 1.47%) than in noncombined reports (17/3000, 0.57%; difference=0.90%; z=3.81; P<.001). In experiment 1, recall differed significantly among the 3 versions of rule-based methods (Q=6.0; P=.0498, Friedman test). The rule-based+GPT-4o method had the highest recall (average rank=1), significantly better than the baseline (average rank=3; P=.04, Nemenyi test). Most (5/6) of the false positives introduced by the GPT-4o information extraction were due to parser limitations hidden by error cancellation. In experiment 2, on Test-1, rule-based+GPT-4o (precision=0.696; recall=0.889; F1-score=0.780) outperformed GPT-4o (precision=0.219; recall=0.889; F1-score=0.352), ClinicalBERT (precision=0.047; recall=0.667; F1-score=0.088), and RoBERTa (F1-score=0.000). On Test-2, rule-based+GPT-4o (precision=0.996; recall=0.925; F1-score=0.959) and GPT-4o (precision=0.979; recall=0.953; F1-score=0.966) outperformed ClinicalBERT (precision=0.984; recall=0.749; F1-score=0.851) and RoBERTa (F1-score=0.013). Both ClinicalBERT and GPT-4o exhibited notable declines in precision on TrainVal and Test-1 compared to Test-2. Both Test-1 data membership (GPT-4o: odds ratio [OR] 239.89, 95% CI 111.05-518.01; P<.001; ClinicalBERT: OR 1924.07, 95% CI 687.46-5383.99; P<.001) and order count per study (GPT-4o: OR 1.79, 95% CI 1.38-2.31; P<.001; ClinicalBERT: OR 2.50, 95% CI 1.64-3.80; P<.001) independently predicted false positive errors in multivariate logistic regression. In subgroup analysis, all models showed reduced precision and F1 in combined-study subgroups.
Conclusions:
The combined radiographic report format poses distinct challenges for both radiology report quality assurance and natural language processing. The combined rule-based and GPT-4o method effectively screens for laterality errors in imbalanced real-world reports. A significant performance gap exists between balanced synthetic datasets and imbalanced real-world data. Future studies should also include real-world imbalanced data.