Related Experiment Video
Updated: Jul 15, 2026

Improved UPLC-UV Method for the Quantification of Vitamin C in Lettuce Varieties Lactuca sativa L. and Crop Wild Relatives Lactuca spp.
Published on: June 30, 2020
Optimised reverse-phase chromatography for clinical detection of vitamins A and E in serum
Aliya Annujma Shahrunizam1, Siok-Fong Chin2, Noraidatulakma Abdullah1
1UKM Medical Molecular Biology Institute (UMBI), Universiti Kebangsaan Malaysia, Jalan Yaacob Latif, Bandar Tun Razak, 56000, Cheras, Wilayah Persekutuan Kuala Lumpur, Malaysia.
None:
Vitamin A and E are indispensable fat-soluble vitamins that play pivotal roles in promoting human health and well-being. Accurate quantification of these vitamins in biological samples is critical. Thus, we aim to develop and optimise a sensitive method suitable for simultaneous analysis of vitamin A and E. We introduced a method for simultaneous detection of Vitamin A and E using reverse-phase high-performance liquid chromatography (RP-HPLC). Calibration curves and quality control samples were prepared using a 4% of Bovine Serum Albumin (BSA) matrix. The analytes and internal standard (ISTD), Dodecanophenone were effectively separated using a polar column and detected via UV detector at wavelengths of 255 nm, 298 nm, and 325 nm respectively, with a total run time of 30 min. Results: The method demonstrated excellent linearity with regression coefficients (r²) > 0.995. The optimisation process of the HPLC method affirmed its precision and reliability, meeting analytical chemistry standards. Subsequently, this validated method was applied to serum samples obtained from patients and a population cohort exhibiting distinct clinical pathologies, including individuals without colorectal cancer (CRC), those with symptomatic and asymptomatic CRC. Conclusions: In conclusion, this HPLC method offers a reliable means for routine quantification of vitamin A and E in human serum, holding promise for enhancing nutritional research and clinical diagnostics. Its novelty lies in the use of a surrogate BSA matrix with a polar RP-HPLC column and multi-wavelength detection, enabling robust quantification of endogenous analytes in clinically relevant cohorts.
More Related Videos
05:03Author Spotlight: Investigating Physiological Functions of Vitamin A Transporters Using HPLC-Based Vitamin A Profiling
Published on: December 27, 2024
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Automated Microbial Diagnostics