PLSELM: A lightweight modeling approach for low-data calibration in near-infrared spectroscopy
Xiaqiong Fan1, Lijin Shang1, Shuo Zhao1
1School of Artificial Intelligence and Big Data, Henan University of Technology, Zhengzhou, 450001, PR China.
Background:
Near infrared (NIR) spectroscopy is widely used as a rapid analytical technique in various fields for its advantages of on-line monitoring and non-destructive testing. It can provide rich chemical information and is of great significance for studying the structure, composition and changes of substances. Reliable calibration remains a major challenge in near-infrared (NIR) spectroscopy, especially under low-data conditions or across instruments with varying configurations. To address this, we propose PLSELM, a lightweight modeling calibration method, which combines Partial Least Squares (PLS) score matrices and Ensemble Extreme Learning Machine (ELM).
Results:
To address this, we propose PLSELM, a lightweight modeling calibration method, which combines Partial Least Squares (PLS) score matrices and Ensemble Extreme Learning Machine (ELM). By modeling the relationship between latent PLS features and concentration values, PLSELM provides a fast, robust, and transferable calibration framework. To evaluating the performance, five diverse NIR spectral data, including 21 sets of concentration indicators from 10 different spectrometers, were used for benchmarking comparison. These NIR spectra have different wavelength ranges, resolutions, lengths, and a wide range of concentrations. Results demonstrate that PLSELM has excellent calibration performance, outperforming conventional PLS, Support Vector Regression, and deep learning-based models. PLSELM also has great suitability in low-data learning and calibration transfer analysis. In addition, PLSELM model has good robustness, which is manifested in that it is not sensitive to the randomness of sample division and the randomness of hidden layer nodes. PLSELM only took 0.5 s to finished the PLSELM and PLS models on corn data.
Significance:
The comprehensive comparison results indicate that the PLSELM method is a robust NIR calibration method, which performs well in various spectral wavelength ranges, resolutions, lengths, and a wide range of concentrations. In summary, PLSELM offers a practical and scalable solution for NIR calibration, with excellent potential for use in real-world analytical applications involving limited data or heterogeneous instruments.
More Related Videos
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
10:25Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements
Published on: June 28, 2016
Related Concept Videos
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
IR Spectrometers
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...