Related Experiment Video
Updated: Jan 12, 2026

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Devices for Neonatal Peripheral Catheterization and Tip Confirmation: A Systematic Review and Meta-Analysis
Kristina Shcherbatiuk1, Clelia Magagnoli2, Francesco Susca3
1Department of Gynecology and Obstetrics, J.W. Goethe-University Frankfurt, Frankfurt, Germany.
Device-assisted techniques for neonatal peripheral intravenous catheterization may improve first-attempt success and reduce procedure time. However, evidence on safety outcomes like thrombosis and infection remains limited, necessitating further high-quality trials.
Area of Science:
- Neonatal Medicine
- Medical Devices
- Clinical Trials
Background:
- Peripheral intravenous catheterization in neonates is challenging due to small vessels, often resulting in multiple attempts and complications.
- Device-assisted techniques are increasingly explored to improve success rates and minimize harm.
Purpose of the Study:
- To evaluate the benefits and harms of device-assisted versus standard peripheral intravenous catheterization techniques in neonates.
- To synthesize evidence from randomized controlled trials (RCTs) on device-assisted catheterization outcomes.
Main Methods:
- A systematic search of multiple databases including MEDLINE, Embase, and ClinicalTrials.gov was conducted up to October 2024.
- Data from 12 RCTs involving 1,251 neonates were collected and analyzed following Cochrane methodology.
- Studies included device use for placement, tip confirmation, or both, with some utilizing ultrasound guidance.
Main Results:
- Device-assisted catheterization may increase first-attempt success (RR: 1.18-1.20) and reduce procedure time.
- Significant reductions were observed in hematoma (RR: 0.32), bleeding (MD: -0.68), and phlebitis (RR: 0.19).
- Evidence for outcomes such as thrombosis, catheter-related bloodstream infection, and arrhythmia was of very low certainty.
Conclusions:
- Device-assisted catheterization shows potential for improving first-attempt success and reducing procedure time in neonates.
- Current evidence regarding the safety of these devices is limited and of low certainty.
- High-quality RCTs with standardized outcome measures are essential to provide more definitive evidence.
Related Concept Videos
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization I: Pre-Procedure Overview