Related Experiment Video
Updated: Jan 12, 2026

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Pulse Arrival Velocity for Tracking Exercise-Induced Blood Pressure Changes in Children and Adolescents
Luke E Ryan1, Melanie M Clarke1, Daniel Ray1
1Heart Research, Murdoch Children's Research Institute, Parkville, VIC, Australia.
Background:
The potential of cuffless blood pressure (BP) monitoring in children and adolescents is unclear. Although measurement of pulse arrival time (PAT) underlies many cuffless BP technologies, the pulse propagation distance (L) (from heart to measurement location) varies significantly during childhood growth and is likely to confound the desired relationship between PAT and BP in population-based algorithms. This study investigated whether the newly proposed pulse arrival velocity (PAV) (PAV=L/PAT) holds potential for improved tracking of exercise-induced BP changes in children and adolescents.
Method:
In 38 included paediatric participants (aged 12.3±3.9 years) undergoing Bruce protocol exercise testing, regression and leave-one-out cross-validation analyses were used to assess performance of PAT and PAV for estimating exercise-induced BP changes. The results were contextualised to BP validation standards.
Results:
With exercise, systolic BP increases of 36.1±15.8 mmHg were estimated by PAT-based and PAV-based models, with errors of 0.0±9.1 and 0.0±7.6 mmHg, respectively; the latter falling within the Association for the Advancement of Medical Instrumentation (AAMI) criteria of 5±8 mmHg, with high correlation (r=0.87). Diastolic BP changes (12.1±9.7 mmHg) were also estimated by PAV within the AAMI criteria (0.0±7.0 mmHg) but with modest correlation (r=0.51). Including heart rate, age, sex, or height did not improve model performance. PAV outperformed baseline models for systolic but not diastolic BP.
Conclusions:
PAV shows potential for systolic BP tracking during exercise in children and adolescents. By accounting for variability in propagation length, PAV may provide better results than PAT in cuffless BP technology.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...

