Reference values for shear wave elastography, shear wave dispersion and attenuation imaging in healthy paediatric

Michael Zellner1, Magdalena Schmidt2, Florian Huber3

  • 1Department of Diagnostic Imaging, University Children's Hospital Zurich, Lenggstrasse 30, Zurich, 8008, Switzerland. michael.zellner@kispi.uzh.ch.

Pediatric Radiology
|November 1, 2025
PubMed

Insights

This study establishes reference values for advanced ultrasound techniques in children, finding that age and sex influence results. These findings are crucial for accurate paediatric liver disease diagnosis using shear wave elastography (SWE), shear wave dispersion (SWD), and attenuation imaging (ATI).

Area of Science:

  • Paediatric Radiology
  • Hepatology
  • Medical Imaging

Background:

  • Paediatric liver disease, including metabolic dysfunction-associated steatotic liver disease, is increasing.
  • Reliable, non-invasive diagnostic tools are needed for children.
  • Advanced ultrasound techniques like shear wave elastography (SWE), shear wave dispersion (SWD), and attenuation imaging (ATI) show promise but lack normative paediatric data.

Purpose of the Study:

  • To establish age-specific reference values for SWE, SWD, and ATI in healthy children.
  • To evaluate the influence of age, sex, BMI, and fasting duration on these ultrasound parameters.

Main Methods:

  • Retrospective analysis of ultrasound data from 264 healthy children.
  • Standardized liver ultrasound protocol with multiple ATI, SWE, and SWD measurements.
  • Statistical analysis to correlate imaging parameters with patient characteristics.

Main Results:

  • Median ATI: 0.54 dB/cm/MHz, SWE: 1.24 m/s, SWD: 11.70 (m/s)/kHz.
  • ATI and SWD negatively correlated with age; SWD also negatively correlated with BMI z-score and was lower in females.
  • SWE showed a weak positive correlation with measurement depth; fasting duration had no significant impact.

Conclusions:

  • Provides essential reference values for paediatric SWE, SWD, and ATI.
  • Age and sex are significant factors influencing SWD and ATI.
  • Emphasizes the need for age-specific interpretation of paediatric liver ultrasound findings.