Patient Reported Experiences and Comfort Associated with Intravitreal Injection Technique: A Cross-Sectional Survey

Elahhe R Afkhamnejad1, Zainub A Abdullah1, Orion M Q Nguyen2

  • 1University of Texas Medical Branch Galveston, Galveston, TX, USA.

PubMed

Purpose: To better understand patient experiences associated with intravitreal anti-vascular endothelial growth factor (anti-VEGF) injection techniques. Methods: A total of 1111 patients receiving anti-VEGF injections at 5 Retina Consultants of Texas clinic locations completed surveys about their experiences during and after injection. Responses were compared using t-test, analysis of variance, and Tukey-Kramer test. Results: Patients rated overall discomfort with injection techniques as a mean visual analog scale score < 2 (scale 1-10, ranging from mild to worst possible). Techniques for anesthetization, lid retraction, and povidone-iodine (Betadine) application varied. Lidocaine pledgets were associated with the most discomfort (P < .05). Patient preference was significantly higher for manual lid retraction over speculum use (P = .0017). Betadine-soaked cotton tips were considered significantly more comfortable than Betadine drops, and drops more comfortable than Betadine swabs (each P < .05). Regarding side effects ever experienced after injection, subconjunctival hemorrhages were reported by 64.0% of participants (n = 702), floaters by 64.4% (n = 685), and eye irritation by 51.1% (n = 530), resolving within 2 days for 37.9% (n = 215), 51.1% (n = 334), and 48.6% (n = 254), respectively. Of returning participants, 41.1% found injections administered by physicians on the survey day more comfortable than injections administered by previous physicians. Common complaints included inadequate anesthesia and irritation from Betadine. Conclusions: Most patients tolerate anti-VEGF injections well, with minimal side effects. Surveyed patients preferred topical gel or subconjunctival injections, manual lid retraction, and Betadine-soaked cotton tips. Future studies may consider the safety associated with each technique.

Related Concept Videos

Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure01:10

Pre-Procedural Guidelines for Assessing Blood Pressure

Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the patient.
Assessment of the Cardiovascular System III: Palpation01:27

Assessment of the Cardiovascular System III: Palpation

Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Imaging Studies VII: Vascular Imaging01:19

Imaging Studies VII: Vascular Imaging

DefinitionRenal angiography, also known as renal arteriography, is an imaging technique used to obtain a comprehensive view of blood flow and the vascular structure of blood vessels in the kidneys and surrounding areas.PurposeRenal angiography detects blood vessel abnormalities in the kidneys, such as aneurysms, stenosis, thrombosis, vascular tumors, and renal artery stenosis. It evaluates kidney function and guides interventional treatments like angioplasty or stent placement.Pre-Procedure...