Effects of Short-Term Exposure to Air Pollutants on Real-Time Blood Pressure: A Wearable Device-Based Study in China
Abstract:
Air pollutants have been known as the most persistent environmental risk factors of elevated blood pressure (BP). However, most of the existing studies measured resting BP only, which is not accurate as ambulatory BP. This study investigated the effects of short-term exposure to air pollutants on ambulatory BP. Wearable devices were used to measure personal ambulatory systolic BP (ASBP) and diastolic BP (ADBP) and movement trajectories of 172 participants for one week, with a 1-min interval. Daily concentrations of the six major air pollutants were estimated at a spatial resolution of 1 km. Linear mixed-effect models and distributed lag non-linear models estimated the associations between air pollutant exposure and ambulatory BP. ASBP was positively associated with PM2.5 (β = 0.010 [95% CI: 0.005, 0.015]), PM10 (β = 0.006 [0.005, 0.008]), and SO2 (β = 0.046 [0.021, 0.071]), and negatively with NO2 (β = -0.009 [-0.017, -0.001]); ADBP was positively associated with PM2.5 (β = 0.008 [0.005, 0.010]) and PM10 (β = 0.003 [0.002, 0.004]), and negatively with NO2 (β = -0.008 [-0.012, -0.004]), O3 (β = -0.002 [-0.004, -0.001]), and CO (β = -0.366 [-0.652, -0.081]). At 14-h lag, ASBP and ADBP were positively associated with PM10 and O3, and negatively with NO2. The cumulated exposure to PM10 and CO was associated with ambulatory BP at all levels of concentration, while SO2 was associated with ambulatory BP only when the concentration was over 15 μg/m3. The findings have important implications for BP management and hypertension prevention, by providing solid evidence for developing cost-effective strategies of minimizing adverse environmental exposure and improving health equity.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement