Related Experiment Video
Updated: Jan 12, 2026

Measurement of Vibration Detection Threshold and Tactile Spatial Acuity in Human Subjects
Published on: September 1, 2016
Vibration, temperature, and humidity influence the perception of electrocutaneous stimulation for occupational
Eva-Maria Dölker1, Daniel Gröllich2, Martin Schmauder2
1Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693, Ilmenau, Germany. eva-maria.doelker@tu-ilmenau.de.
Abstract:
Electrocutaneous stimulation can be used to warn workers in hazardous situations. To determine parameters for the operating ranges of such warning systems we investigated the influences of vibrations, temperature, and humidity on the perception, attention, muscle twitch, and intolerance thresholds of healthy volunteers in a multi-center study. In a study on 94 participants, vibrations with amplitudes of 2 mm, 5 mm, and 8 mm and at frequencies of 8 Hz and 9.5 Hz were applied to the right arm. In a second study, 52 participants experienced temperature and humidity variations within a climate chamber in four conditions: dry cold (13.8 ± 1.6 [Formula: see text]C, 33.9 ± 9.2% relative humidity (RH)), dry warm (41.3 ± 1.7 [Formula: see text]C, 24.6 ± 5.8% RH), wet cold (12.0 ± 1.6 [Formula: see text]C, 88.5 ± 8.2% RH), and wet warm (41.3 ± 2.1 [Formula: see text]C, 65.5 ± 9.0% RH). In both studies, the upper right arm was electrically stimulated with electrodes of size 25 mm×40 mm, and thresholds were determined. Perception, attention, and intolerance thresholds increased with vibration amplitude and frequency from median values of 5 mA, 9.9 mA and 19.3 mA for perception, attention and intolerance thresholds during rest to 14.6 mA, 20 mA and 21 mA during vibration amplitude of 8 mm and frequency of 9.5 Hz. Perception thresholds slightly increased with decreasing temperature with median values of 4.1 mA during dry cold vs. 3.8 mA during dry warm condition and 4.0 mA during wet cold vs. 3.8 mA during wet warm condition for an electrode pair at a lateral position. Muscle twitch thresholds slightly increased with increasing temperature at the lateral electrode pair with median values of 17.4 mA during dry cold vs. 18.8 mA during dry warm condition and 17.5 mA during wet cold vs. 18.7 mA during wet warm condition. For both studies, women showed smaller perception and attention thresholds. For illustration, in study 1, the median values of the perception threshold during rest were 4.1 mA for women and 5.7 mA for men, whereas the median values for the attention threshold were 9.1 mA for women and 11.4 mA for men, respectively. Additionally, women experienced less muscle twitching. To exemplify this, 50% of the women experienced muscle twitches compared to 66% of the men at a lateral electrode pair in study 2. We conclude that the operating range of future electrical warning systems needs to be flexibly adjusted to the working conditions. The influence of the climate conditions was minor, suggesting that electrocutaneous warning systems can operate robustly across diverse environments. This supports their practical applicability and motivates future research on optimized dry or textile-based electrodes to enhance usability in real-world settings.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Responses to Heat and Cold Stress
Thermosensation
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...