Performance Comparison Between Two Versions of a Commercial Artificial Intelligence System for Chest Radiograph
Carolina Diaz Angulo1, Teodoro Martín-Noguerol2, Felix Paulano-Godino2
1Department of Radiology, HT Médica Jaén Las Nieves, C. Carmelo Torres, 2, Jaen, 23007, Spain. c.diaz@htmedica.com.
Abstract:
The purpose of the study was to compare the diagnostic performance of version 1.5.0 and version 1.5.4 of Gleamer ChestView, a deep learning-based artificial intelligence system for chest X-ray analysis, across multiple thoracic findings. A retrospective multicenter study including 187 chest radiographs from six centers using equipment from four manufacturers (Agfa-Gevaert N.V., Mortsel, Belgium; IRay Technology Co., Ltd., Shanghai, China; LG Electronics Inc., Seoul, South Korea; Siemens Healthineers, Erlangen, Germany) was conducted. Inclusion criteria were chest radiographs acquired during the month following the implementation of version 1.5.0 of Gleamer ChestView. Each radiograph was analyzed by both versions. Ground truth was established through chest CT performed within a week of the radiograph when available (49 cases) and consensus by three board-certified general radiologists in the remaining 138 cases. Standard reference included 57 positive cases (pleural effusion, alveolar disease, mediastinal mass, pneumothorax, pulmonary nodule) and 130 normal studies. Performance metrics (sensitivity, specificity, precision, F1 score) were calculated for each version. A total of 187 chest radiographs were analyzed (101 females, 86 males; mean age 59.2 ± 19.7 years; range 15-95). Overall performance improved from version 1.5.0 to 1.5.4, with higher accuracy (87.7% vs 92.5%), precision (75.0% vs 85.2%), specificity (86.9% vs 93.1%), and F1 score (0.816 vs 0.881). For nodule detection, version 1.5.4 showed increased precision (47.8% to 73.3%) while maintaining sensitivity. Gleamer ChestView version 1.5.4 demonstrated improved lesion-specific performance compared to version 1.5.0, with fewer false positives and higher diagnostic confidence. These findings support the implementation of updated AI systems following systematic version-to-version validation.
More Related Videos
07:13Comparison of Predictive Performance of Three Lymph Node Staging Systems in Colorectal Signet Ring Cell Carcinoma Based on Machine Learning Model
Published on: April 18, 2025
05:33Introduction of an Integrated Pathology Image Management, Artificial Intelligence, and Reporting System
Published on: July 11, 2025
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Imaging Studies for Cardiovascular System IV: CMRI