Related Experiment Video
Updated: Jan 12, 2026

Author Spotlight: Using Hyperpolarized Xenon-129 MRI to Study Lung Diseases
Published on: January 5, 2024
Correction of aliasing artifact in accelerated echo-planar imaging
Silu Han1, Chidi P Ugonna1, Nan-Kuei Chen2
1Department of Biomedical Engineering, University of Arizona, Tucson, AZ, USA.
Purpose:
To develop a comprehensive reconstruction pipeline that simultaneously addresses 2D Nyquist and aliasing artifacts in echo-planar imaging (EPI) data acquired using various schemes, including single-shot, multi-shot, parallel, and multi-band EPI.
Methods:
We introduce a novel 2D Nyquist artifact correction method that extends our previously reported phase-search reconstruction approach. A series of phase-corrected images are generated using a range of candidate phase values, and the corresponding coil sensitivity profiles are compared with known profiles to estimate an optimal 2D Nyquist phase correction map. In addition, we propose an integrated reconstruction procedure that corrects aliasing artifacts arising from 2D Nyquist effects, shot-to-shot motion-induced phase variations, and both in-plane and through-plane acceleration schemes. The proposed methods were evaluated using resting-state fMRI data from 30 healthy volunteers.
Results:
The proposed method substantially reduced residual artifacts in EPI data, as measured by the ghost-to-signal ratio. The resulting default-mode network maps showed improved correspondence with known reference networks compared to those obtained using conventional 1D Nyquist artifact correction methods.
Conclusion:
The developed reconstruction pipeline effectively corrects multiple sources of aliasing artifacts in EPI data, offering improved image quality and functional sensitivity across a wide range of EPI acquisition schemes.
More Related Videos
10:23Equipment Setup and Artifact Removal for Simultaneous Electroencephalogram and Functional Magnetic Resonance Imaging for Clinical Review in Epilepsy
Published on: June 23, 2023
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
NMR Spectrometers: Resolution and Error Correction
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...