From Cuffs to Code: Machine Learning in Non-Invasive Blood Pressure Monitoring
Ravi Pal1, Joshua Le2, Theodora Wingert1
1Department of Anesthesiology and Perioperative Medicine, David Geffen School of Medicine, University of California Los Angeles, California, United States of America.
Abstract:
Blood pressure (BP) measurement in both acute care and outpatient settings is essential, as conditions like hypertension and hypotension are common and often asymptomatic until organ damage occurs. These conditions significantly increase the risk of morbidity and mortality but can be effectively managed through early detection and treatment. For decades, cuff-based devices have dominated non-invasive BP monitoring; however, they are often bulky, inconvenient, and limited to intermittent measurements. In recent years, machine learning (ML) and artificial intelligence (AI)-based approaches for BP estimation from non-invasive physiological signals-such as electrocardiography (ECG) and photoplethysmography (PPG)-have generated considerable interest. These innovations promise to enable continuous, cuff-less BP monitoring, expanding the reach of BP assessment into wearable devices and facilitating more dynamic, patient-centered care. This review provides a comprehensive overview of the evolution of non-invasive BP measurement technologies, with particular emphasis on emerging AI-driven methods and trends shaping the development of continuous and wearable solutions. While these technologies offer new opportunities for continuous monitoring and patient engagement, this review focuses on their conceptual and technological development rather than detailed performance evaluation or clinical validation.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure