Related Experiment Video
Updated: Jan 12, 2026

Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
Published on: September 6, 2024
Motion and Flow Robust Free-Breathing Diffusion Kurtosis Imaging of the Kidney
Nima Gilani1,2, Malika Kumbella1,2, Mary Bruno1,2
1The Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, NYU Grossman School of Medicine, New York, New York, USA.
None:
The development of noninvasive MRI biomarkers as surrogates of histopathological features in kidney tissue requires detailed explorations of contrast. Therefore, we studied kidney diffusion kurtosis imaging (DKI) with a wide array of encodings, including flow compensation, variable directional sampling, and cardiac gating regimes. Twelve healthy volunteers underwent DKI at 5-10 diffusion weightings (b-values) ranging from 0 to 1200 smm-2 with 12 or 30 directional samplings, bipolar or flow-compensated diffusion gradient waveforms, and at systolic or diastolic cardiac phases. DKI biomarkers, mean diffusivity (MD) and kurtosis (MK), were interrogated using a directionally robust fitting algorithm compared to conventional fits. The combination of flow compensation and cardiac triggering at the diastolic phase in the kidneys reduced flow effects on DKI. In systole, flow-compensated waveforms significantly reduced MD and MK for both cortex and medulla: cortex MD: 3.00 versus 2.55 μm2 ms-1, medulla MD: 2.80 versus 2.39 μm2 ms-1, cortex MK: 0.58 versus 0.45, and medulla MK: 0.60 versus 0.47 (all p < 0.05). Flow suppression alleviated requirements for processing the DKI at higher minimum b-values, as neither MD nor MK significantly differed at the diastolic phase for minimum b-values of 0 versus 200 smm-2: cortex MD: 2.30 versus 2.28 μm2 ms-1, p = 0.278; medulla MD: 2.29 versus 2.28 μm2 ms-1, p = 0.437; cortex MK: 0.37 versus 0.36, p = 0.308; and medulla MK: 0.40 versus 0.40, p = 0.904. Flow-compensated waveforms mitigate cardiac and respiratory motion-related artifacts at higher diffusion encodings in addition to microcirculation effects. The robust fitting initially developed for brain DKI is highly applicable to the kidneys because it disentangles tissue-specific directional diffusion information from artifacts.
Related Concept Videos
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies VII: Vascular Imaging
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies II: Ultrasonography

