Related Experiment Video
Updated: Jan 12, 2026

Measurements of Local Instantaneous Convective Heat Transfer in a Pipe - Single and Two-phase Flow
Published on: April 30, 2018
Experimental assessment of passive radiator parameters using normal-incidence sound transmission measurements
Brian E Anderson1, Spencer T Neu1, Joshua F Gregg1
1Acoustics Research Group, Department of Physics and Astronomy, Brigham Young University, N283 Eyring Science Center, Provo, Utah 84602, USA.
Abstract:
Passive radiators are notoriously difficult to characterize because one cannot effectively assess their mechanical parameters with loudspeaker electrical impedance techniques and no motors. This paper discusses the details of passive radiator and dynamic loudspeaker driver parameter measurements through practical experiments conducted with a plane wave tube, the two-microphone transfer function technique, and the two-load method to remove the need for an ideal anechoic termination. A previous theoretical paper demonstrated how normal-incidence transmission losses through these devices in an anechoically terminated tube could yield their mechanical and electrical parameters [Leishman and Anderson, J. Acoust. Soc. Am. 134(1), 223-236 (2013)]. The mechanical parameters follow from an open-circuit transmission loss condition, whereas a driver's electrical parameters follow from an additional closed-circuit condition. This paper presents several experimental results and compares extracted parameters to those derived from electrical impedance measurements and destructive methods. In addition to other parameters, the masses of diaphragm assemblies show favorable agreement. The presented techniques effectively assess passive radiator parameters without employing active driver configurations and then removing their motors, which changes the measured properties. PACS numbers: 43.38.Ja, 43.20.Ye, 43.20.Mv, 43.55.Rg.
Related Concept Videos
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Absorption of Radiation

