Related Experiment Video
Updated: Jan 12, 2026

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Intraprocedural Transesophageal Echocardiography Ensures Accurate Anchoring During Transcatheter Intervention for
Katie Wing-Sum Fan1, Kevin Ka-Ho Kam1, Ka Lung Chui1
1Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong SAR, China.
Objective:
This case report elucidates the indispensable role of structured transesophageal echocardiography imaging in guiding the implantation of the JenaValve, a transcatheter device designed for severe native aortic regurgitation via its unique locator-based anchoring system.
Key Steps:
First, use the midesophageal aortic valve short-axis view to confirm capture of the left and noncoronary cusps. Second, employ a modified transgastric aortic valve short-axis 90° view to visualize the often obscured right coronary cusp. These complementary views can verify precise locator engagement on all 3 leaflets before final deployment.
Potential Pitfalls:
Overreliance on fluoroscopy can lead to valve malposition or migration due to poor cusp visualization. Excessive manipulation during positioning can dislodge locators into the left ventricular outflow tract.
Take-Home Message:
A systematic, multiview transesophageal echocardiography approach is critical to confirm successful leaflet capture and ensure stable JenaValve deployment in noncalcified structures, mitigating major risks of device failure.
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation I: Introduction
Cardiac Catheterization I: Pre-Procedure Overview