Deep Resolve Boost in 2D MRI for Neuroradiology: A Comparative Evaluation of Diagnostic Gains and Potential Risks
Arsany Hakim1, Roman Rohner2,3, Anna Winklehner2
1From the University Institute of Diagnostic and Interventional Neuroradiology (A.H., R.R., A.W., C.L., R.W., J.G., E.P.), Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland arsany_hakim@yahoo.com.
Background And Purpose:
Deep Resolve Boost (DRB) applied to accelerated acquisition (ACC) offers the potential to reduce MRI acquisition time and improve image quality. However, studies on the potential impact on artifacts, anatomic delineation, and the depiction of imaging findings are scarce. This study aims to fill this gap and evaluates the clinical performance of DRB-ACC in 2D MRI sequences.
Materials And Methods:
In this prospective observational study, 256 paired 2D sequences (T2/turbo inversion recovery magnitude, and FLAIR) were acquired from 200 patients undergoing routine neuroradiologic MRI on a 3T scanner. For each examination, both standard and DRB-ACC (predominantly high strength) were acquired in the same session using identical scanner settings, except for acceleration factor; same surface coil, sequence orientation, and slice thickness. Image quality, anatomic structure delineation, artifact presence, and lesion conspicuity were independently assessed by 2 readers using standardized scoring.
Results:
DRB-ACC sequences demonstrated good or fair image quality in 94.5% of cases, with improved or unchanged quality compared with standard acquisition in 95.7% of sequences. However, anatomic delineation was inferior in key regions such as the hippocampus, brainstem, and cerebellum. Artifacts were more pronounced in 27.3% and newly introduced in 84.8% of the accelerated DRB sequences, commonly affecting the brainstem and deep gray matter. Lesion depiction was equivalent to standard images in 91.6% of cases, with limited instances of improved (7.2%) or degraded (1.2%) delineation.
Conclusions:
DRB-ACC enables acceleration of 2D MRI while maintaining image quality and lesion visibility. At the same time, the presence of artifacts and reduced delineation of certain anatomic structures underscores the need for caution in the interpretation of image findings and selective use in clinical routine, particularly in clinical scenarios requiring high anatomic detail such as for epilepsy screening, or in cases with suspected brainstem pathology.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET