Related Experiment Video
Updated: Jan 12, 2026

Electroantennography-based Bio-hybrid Odor-detecting Drone using Silkmoth Antennae for Odor Source Localization
Published on: August 27, 2021
Enhanced Selectivity Electronic Nose Systems for Agricultural Ammonia Gas Detection via a co-designed WO3-ZnO Sensor
Mengying Du1, Mukhtar Iderawumi Abdulraheem2,3, Lulu Xu1
1Henan International Joint Laboratory of Laser Technology in Agriculture Sciences, College of Mechanical and Electrical Engineering, Henan Agricultural University, Zhengzhou, 450002, China.
Abstract:
Electronic noses (e-noses) offer a practical solution for real-time monitoring of ammonia (NH3) in agricultural environments, where NH3 often coexists with interfering gases such as CO2, CH4, and H2S. However, semiconductor-based gas sensors commonly used in e-nose systems suffer from inherent cross-sensitivity, which reduces measurement accuracy. This study investigates the cross-sensitivity of NH3 detection and introduces a mitigation strategy through convolutional neural networks (CNNs) for sensor data fusion. Experimental results show that WO2-based sensors exhibit strong NH3 selectivity, with response ratios of 7.3:1 against CH4 and 17.8:1 against H2S. Density functional theory (DFT) analysis confirmed that the WO3 sensor exhibited strongest NH3 binding energy (- 1.45 eV), compared to SnO2 (- 1.10 eV), explaining the observed selectivity. Measurement uncertainties (± 8%) were quantified under varying humidity (30-90% RH) and temperature (10-40 °C) using a weighted least squares error propagation model. A quasi-2D sensor array improved NH3 classification accuracy to 96.4% (7.2% increase) while reducing concentration errors by 50.8%, as validated by linear discriminant analysis. Long-term stability tests demonstrated that SnO2 sensors maintained a low baseline drift of 0.18%/day over 180 days, outperforming CH4 (0.31%/day) and ZnO (0.42%/day) sensors. Furthermore, the CNN model, trained on multi-sensor time-series data, achieved 91.7% accuracy in mixed-gas environments by capturing non-linear response patterns, ensuring reliable NH3 quantification despite interferents. These findings highlight the promise of CNN-enhanced e-nose systems for precise NH3 monitoring in complex agricultural settings, addressing key challenges of cross-sensitivity and environmental stability.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Key Elements for Plant Nutrition
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
NMR Spectroscopy Of Amines