Related Experiment Video
Updated: Jan 12, 2026

In Situ Monitoring of the Accelerated Performance Degradation of Solar Cells and Modules: A Case Study for CuIn,GaSe2 Solar Cells
Published on: October 3, 2018
Performance evaluation and degradation analysis of grid connected photovoltaic systems for energy efficient buildings
Putri Nor Liyana Mohamad Radzi1, Saad Mekhilef2,3, Noraisyah Mohamed Shah4
1Power Electronics and Renewable Energy Research Laboratory (PEARL), Department of Electrical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, 50603, Malaysia. 17013615@siswa.um.edu.my.
Abstract:
The adoption of photovoltaic systems is growing as part of the global shift to renewable energy. Integrating photovoltaic systems into buildings enhances sustainability by enabling on-site generation, reducing energy costs, and promoting environmental preservation. Ensuring long-term reliability requires a comprehensive analysis. This study analyzes a grid-connected photovoltaic system, operated and maintained by the Power Electronics and Renewable Energy Laboratory (PEARL) for research. The system consists of Poly-Crystalline (Array 1) and Mono-Crystalline silicon (Array 2) panels with a total capacity of 3.575 kWp, monitored over 36 months from January 2020 to December 2022. Eleven performance parameters were analyzed following the IEC 61724 guidelines. Additionally, Modified Akima cubic Hermite (MAKIMA) methods were utilized to forecast the degradation rate of each photovoltaic technologies degradation rates in 2023. The results indicate that Array 1 and Array 2 produced an average AC energy output of 3881.67 kWh and 1120.48 kWh, with 86.74% and 56.30% performance ratios, respectively. The forecasting analysis predicted degradation rates of 10.58% for Array 1 and 11.99% for Array 2. These findings provide valuable information on the durability and efficiency of PV materials in tropical climates, contributing to optimized system performance, longevity, and material selection in high-temperature, high-humidity environments.
More Related Videos
09:00Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass ADG Fresnel Lens for Concentrating Photovoltaics
Published on: October 27, 2017
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Related Concept Videos
Maximum Power Flow and Line Loadability
Power Factor Correction
Power System Distribution
The transmission system is designed...
The Power Flow Problem and Solution
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Secondary Distribution
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...