Deep Learning Denoising Algorithm for Improved Assessment of Coronary Arteries in Transcatheter Aortic Valve
Ludovica R M Lanzafame1, Sebastian Steinmetz2, Tommaso D'Angelo1
1Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy (L.R.M.L., T.D., S.M.).
Rationale And Objectives:
To assess the impact of a deep learning-based noise reduction (DLD) technique on image quality and diagnostic accuracy for the evaluation of coronary arteries in transcatheter aortic valve implantation (TAVI) CT imaging.
Materials And Methods:
Two hundred patients with severe aortic stenosis who underwent CT scans for pre-TAVI planning between October 2022 and April 2024 were retrospectively enrolled. Conventional images were reconstructed and denoised images were generated using dedicated software. Objective image quality was evaluated by measuring the mean Hounsfield unit (HU) and standard deviation (SD) in regions of interest within the aortic root, coronary arteries, and subcutaneous fat to calculate signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). For subjective assessment, two readers used a 5-point Likert scoring system to evaluate sharpness, noise, contrast and overall image quality. The diagnostic performance of both datasets was assessed using invasive coronary angiography as reference standard.
Results:
Denoised reconstructions showed significantly higher SNR (37.5±12.8 vs.12.3±4.1) and CNR (45.3±15.4 vs. 14.7±4.4), and lower noise (16.9±7.9 vs. 47.9±11.6 HU) (all p<0.001). Subjective assessment demonstrated that denoised images received the highest score for sharpness, noise, contrast and overall image quality (all p<0.001). For the evaluation of diagnostic accuracy, a total of 800 vessels and 1787 segments were analyzed. The per-segment diagnostic performance of the DLD for detection of CAD revealed an AUC of 90% (95% CI: 88.5-91.3), with accuracy of 93.9% (95% CI: 92.7-95), 85.7% (95% CI: 78.7-90.4) sensitivity and 94.7% (95% CI: 93.5-95.7) specificity, in the absence of a statistically significant difference compared with the evaluation performed on standard images (p=0.056).
Conclusion:
The DLD substantially improves image quality without affecting diagnostic accuracy for the evaluation of coronary arteries in patients undergoing pre-TAVI CT scans.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
04:40Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...