Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Correlation between carotid Doppler ultrasound-derived parameters and cardiac output measurements: a systematic
Feng Chen1, Tao-Tao Peng1, Hua-Wei Liu1
1Department of Anesthesiology, The Second Affiliated Hospital of Army Medical University, Chongqing, China.
Background:
The utility of carotid Doppler ultrasound (CDU) as a noninvasive tool for cardiac output (CO) monitoring has been a subject of considerable debate. This meta-analysis was conducted to synthesize the available evidence and quantitatively assess the correlation between CDU-derived parameters and standard CO measurements.
Methods:
We searched the databases of PubMed, EMBASE, Science Direct/Elsevier, MEDLINE, Web of Science, Cochrane Library, China National Knowledge Infrastructure, and China Biology Medicine from the date of inception up to August 2024. Data were analyzed by extracting Pearson's or Spearman's correlation coefficients from each study and converting them to Fisher's Z. The pooled r value was calculated using Fisher's Z and standard error. STATA (Version 15.0) software was used to facilitate data synthesis.
Results:
After screening titles and abstracts, 476 studies required full-text evaluation. Based on the inclusion and exclusion criteria, 17 observational studies were selected for meta-analysis. The results indicated a positive correlation between CDU-derived parameters and CO measurements [0.53, 95% confidence interval (CI): 0.39-0.64], with parameter change values being more relevant than absolute values (0.76, 95% CI: 0.49-0.90) versus (0.43, 95% CI: 0.27-0.57). Furthermore, the carotid velocity-time integral (CVTI) exhibited a stronger correlation (0.81, 95% CI: 0.62-0.91) than the other three parameters (carotid-corrected flow time 0.59, 95% CI: 0.31-0.77), carotid peak systolic velocity (0.40, 95% CI: 0.21-0.57), and carotid blood flow (0.33, 95% CI: 0.12-0.52) in the subgroup analysis. Egger regression analysis and the trim-and-fill method indicated no publication bias (P>0.05).
Conclusions:
CDU-derived parameters demonstrated positive correlations with CO measurements, providing evidence for the use of CDU-derived parameters as surrogate CO monitors.
More Related Videos
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Pathophysiology of Cardiac Performance