Related Experiment Video
Updated: Jan 11, 2026

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
CO2 Isotopologue Quantification Using Direct Frequency Comb Spectroscopy and Machine Learning
Madeleine Cochrane1,2, Sarah K Scholten2,3, Chris Perrella2,3,4
1Australian Institute for Machine Learning (AIML), School of Computer and Mathematical Sciences, University of Adelaide, Adelaide, South Australia 5005, Australia.
None:
The estimation of molecular concentrations in gas mixtures has applications in healthcare, environmental monitoring, and food quality assessment. Direct frequency comb spectroscopy provides benefits as a sensing platform in these application areas due to its accuracy, species selectivity and capacity for broadband analysis and miniaturization. One challenge associated with direct frequency comb spectroscopy is the accurate estimation of the concentration levels of molecules with overlapping absorption features. Traditional analysis methods, such as curve fitting, do not scale well to mixtures containing many different molecules. Here, we use machine learning methods to estimate the concentration level of two isotopologues of carbon dioxide: 12C16O2 and 13C16O2. We compare several machine learning methods for analyzing both transmission spectra and the image output of a virtually imaged phased array spectrometer. Additionally, we evaluate two data augmentation methods to improve the model's generalization ability. Our optimal approach, the transformer method with shifted spectra data augmentation, outperforms curve fitting estimates with a mean absolute error of 14.7 ppm for 12C16O2 and 0.3 ppm for 13C16O2, both 3 orders of magnitude smaller than the equivalent curve fitting values.
More Related Videos
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Emission Spectroscopy: Instrumentation
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)

