Related Experiment Video
Updated: Jul 10, 2026

09:04
Synergizing Antegrade Endoscopic with Bridging Vein Harvesting for Improvement of Great Saphenous Vein Graft Quality from the Lower Leg
Published on: November 19, 2019
9.1K
The preliminary European multi-centre experience with G-Branch Endograft
Marwan Youssef1, Meera Gunaseelan2, Theodoros Kratimenos3
1Department for Vascular and Endovascular Surgery, Asklepios Clinic Nord - Ochsenzoll, Asklepios Hospital Nord, Hamburg, Germany.
VASA. Zeitschrift Fur Gefasskrankheiten
|November 10, 2025
Summary
The G-Branch endograft shows promising short-term results for treating thoraco-abdominal aortic aneurysms (TAAA) and juxta/pararenal abdominal aortic aneurysms (J/PAAA), achieving high technical success and safety in a multicenter study.
Area of Science:
- Vascular Surgery
- Endovascular Repair
- Aortic Aneurysm Treatment
Background:
- Thoraco-abdominal aortic aneurysms (TAAA) and juxta/pararenal abdominal aortic aneurysms (J/PAAA) present complex treatment challenges.
- Novel endovascular devices are crucial for improving outcomes in complex aortic pathologies.
Purpose of the Study:
- To evaluate the short-term safety and efficacy of a novel, customized multibranched G-Branch endograft.
- To assess outcomes for patients undergoing endovascular repair of TAAA and J/PAAA.
Main Methods:
- A multicenter study involving 50 patients treated with the G-Branch endograft between July 2023 and May 2025.
- Patients had either TAAA (31) or J/PAAA (19), with some requiring repair of concomitant iliac or arch aneurysms.
- Procedures included elective one-stage (60%) or staged repair (40%), with data collected prospectively and analyzed retrospectively.
Main Results:
- High technical success rate of 96% (48/50) was achieved.
- Early perioperative complications occurred in 11% of patients, with no spinal cord ischemia.
- Over a mean 7-month follow-up, freedom from branch instability was 99%, with only 4% requiring reintervention for endoleaks.
Conclusions:
- The G-Branch endograft demonstrates safety and high technical success in the preliminary treatment of J/PAAA and TAAA.
- Encouraging short-term outcomes suggest potential for this device in complex aortic aneurysm repair.
- Continued surveillance and extended follow-up are necessary to validate long-term efficacy.