Development of an Improved Stacked U-Net Model for Cuffless Blood Pressure Estimation Based on PPG Signals
Jenn-Kaie Lain1, Chung-An Wang1, Jun-Hao Xu1
1Department of Electronic EngineeringNational Yunlin University of Science and Technology Douliou 640301 Taiwan.
Abstract:
Goal: This study presents an enhanced stacked U-Net deep learning model for cuffless blood pressure estimation using only photoplethysmogram signals, aiming to improve the accuracy of non-invasive measurements. Methods: To address the challenges of systolic blood pressure estimation, the model incorporates velocity plethysmogram input and employs additive spatial and channel attention mechanisms. These enhancements improve feature extraction and mitigate decoder mismatches in the U-Net architecture. Results: The model satisfies the Grade A criteria established by the British Hypertension Society and meets the accuracy standards of the Association for the Advancement of Medical Instrumentation, achieving mean absolute errors of 3.921 mmHg for systolic and 2.441 mmHg for diastolic blood pressure. It outperforms PPG-only spectro-temporal methods and achieves comparable performance to the joint photoplethysmogram and electrocardiogram one-dimensional squeeze-and-excitation network with long short-term memory architecture. Conclusions: The proposed model shows strong potential as a practical, low-cost, and non-invasive solution for continuous, cuffless blood pressure monitoring.
More Related Videos
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...