Integrated Analytical System for Comprehensive Two-Dimensional Enantio-Gas Chromatography and Low-Pressure Gas
Giorgia Rinaldi1, Antonio Ferracane1, Mariosimone Zoccali2
1Messina Institute of Technology c/o Department of ChemicalBiological, Pharmaceutical and Environmental Sciences, former Veterinary School, University of Messina, Viale G. Palatucci snc, 98168 Messina, Italy.
Abstract:
An analytical system was developed to perform both comprehensive two-dimensional enantio-gas chromatography mass spectrometry with the second-dimension column working under low-pressure conditions (eGC×LP-GC-QMS) and low-pressure gas chromatography mass spectrometry (LP-GC-QMS) analysis, without any changes to the instrumental setup. This is achieved using a switching valve, which also allows for back-flushing of the first-dimension column, thereby generating a flexible and powerful analytical platform. The eGC×LP-GC-QMS configuration can provide both targeted and untargeted information in a single run. In this research, it is employed for the analysis of 56 pesticides (without considering isomers), with the added capability of the backflush mode, effectively removing high-boiling compounds extracted from the matrix and improving sample throughput and system robustness, without major concerns regarding sample preparation. The first-dimension is a chiral column, which enables the separation of seven enantiomers: acephate, benoxacor, chlorflurecol, dibrom, fipronil, methamidophos, and propetamphos. The second-dimension is a wide-bore column (5 m × 0.53 mm I.D. × 0.53 μm df) operating under vacuum conditions. Thanks to the use of a switching valve, it is possible to directly perform LP-GC-QMS analysis, enabling the investigation of a broader range of compounds in terms of boiling point. The operability range of volatile analytes was evaluated for both configurations by injecting different alkane mixtures: C7-C30 for the eGC×LP-GC-QMS configuration and C7-C40 for the LP-GC-QMS configuration.
More Related Videos
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
07:49On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Instrumentation