Related Experiment Video
Updated: Jan 6, 2026

Fabrication of High Contrast Gratings for the Spectrum Splitting Dispersive Element in a Concentrated Photovoltaic System
Published on: July 18, 2015
Simultaneous photovoltaic distributed generation and capacitor optimization for enhancing performance indices of
P Rajakumar1, P M Balasubramaniam2, E Parimalasundar3
1Department of EEE, Vel Tech Rangarajan Dr.Sagunthala R&D Institute of Science and Technology, Chennai, India.
None:
This paper presents an effective metaheuristic framework using the Osprey Optimization Algorithm (OOA) for the simultaneous allocation of distributed generation (DG) units and capacitor banks (CB) in radial distribution systems (RDS). The method optimizes the locations and sizing for DG units and CB to minimize active power losses (APL), to reduce voltage deviation (VD), and to enhance voltage stability. The performance of the proposed approach is tested on IEEE 69-bus and 118-bus benchmark RDSs and the real-time Tala Egyptian RDS. The OOA achieved superior results compared to popular heuristic algorithms such as antlion optimizer (ALO), hunter-prey optimizer (HPO), and whale optimizer algorithm (WOA). Specifically, for three units of DG and single capacitor integration in the 69-bus system, OOA reduced the total APL by 75.1%, lowered the total voltage deviation (TVD) by 1.4835 p.u., and improved the total voltage stability index (TVSI) by 3.0229. With optimal assimilation of three units of DG and capacitors each, APL reduction, TVD minimization, and TVSI improvement further extended to 79.9%, 1.5013 p.u., and 2.2787, respectively. Furthermore, OOA validation on a variable-load 69-bus RDS and the real 37-bus Tala Egyptian RDS demonstrated consistent and superior performance, showcasing its robustness. Statistical analyses also confirm OOA's efficiency and ability to solve DG planning in the distribution networks.
More Related Videos
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
09:00Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass ADG Fresnel Lens for Concentrating Photovoltaics
Published on: October 27, 2017
Related Concept Videos
Power Factor Correction
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Fast Decoupled and DC Powerflow
Maximum Power Flow and Line Loadability
Power System Distribution
The transmission system is designed...
The Power Flow Problem and Solution