Analytical modeling of coreless stator axial flux permanent magnet machines under no-load condition

Farhad Rezaee-Alam1

  • 1Department of Electrical Engineering, Lorestan University, Khorramabad, Iran. rezaee.fa@lu.ac.ir.

Scientific Reports
|November 12, 2025
PubMed

Related Concept Videos

Simplified Synchronous Machine Model01:30

Simplified Synchronous Machine Model

The Synchronous Machine Model is a fundamental tool in analyzing and ensuring the transient stability of power systems. This model simplifies the representation of a synchronous machine under balanced three-phase positive-sequence conditions, assuming constant excitation and ignoring losses and saturation. The model is pivotal for understanding the behavior of synchronous generators connected to a power grid, particularly during transient events.
In this model, each generator is connected to a...
736
Wind Turbine Machine Models01:24

Wind Turbine Machine Models

In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
554
Torque On A Current Loop In A Magnetic Field01:13

Torque On A Current Loop In A Magnetic Field

The most common application of magnetic force on current-carrying wires is in electric motors. These consist of loops of wire, which are placed between the magnets with a magnetic field. When current flows through the loops, the magnetic field applies torque, which causes the shaft to rotate, thus converting electrical energy to mechanical energy.
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
5.7K
Equivalent Circuits for Practical Transformers01:28

Equivalent Circuits for Practical Transformers

The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
1.3K
Magnetic Field of a Solenoid01:18

Magnetic Field of a Solenoid

A solenoid is a conducting wire coated with an insulating material, wound tightly in the form of a helical coil. The magnetic field due to a solenoid is the vector sum of the magnetic fields due to its individual turns. Therefore, for an ideal solenoid, the magnetic field within the solenoid is directly proportional to the number of turns per unit length and the current. Conversely, the magnetic field outside the solenoid is zero.
Consider a solenoid with 100 turns wrapped around a cylinder of...
5.6K
Force On A Current Loop In A Magnetic Field01:17

Force On A Current Loop In A Magnetic Field

Magnetic forces on wires carrying current are most frequently applied in motors. A DC motor is a device that converts electrical energy into mechanical work. In motors, wire loops are enclosed in a magnetic field. When current flows through the loops, the magnetic field applies torque, which causes the shaft to rotate. The direction of the current is reversed once the loop's surface area is lined up with the magnetic field, causing a constant torque on the loop. During the process, commutators...
4.0K