Multi-layer self-calibrated algorithm for transabdominal fetal pulse oximetry: simulation and in vivo validation

Jingyi Wu1, Martin P Debreczeny2, Nevan C Hanumara3

  • 1Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, United States of America.

Jphys Photonics
|November 13, 2025
PubMed

Transabdominal fetal pulse oximetry offers a promising approach to non-invasively monitor fetal arterial oxygen saturation (SaO2), potentially enhancing clinical decision-making and reducing unnecessary interventions during delivery. However, accurate estimation of fetal SaO2 (denoted as SpO2 when measured non-invasively) is complicated by the multi-layer maternal-fetal tissue structure, distinct maternal and fetal physiological signals, and inherently low fetal oxygen saturation levels. A multi-layer self-calibrated algorithm was developed by combining the multi-layer modified Beer-Lambert law with an analytical photon partial pathlength model. This approach distinguishes maternal and fetal tissue contributions, enabling more accurate fetal SpO2 estimation. Validation was performed using Monte Carlo photon simulations of multi-layer tissue geometries, where synthetic optical signals representing fetal cardiac pulsations were generated under two fetal depths and randomly varied maternal and fetal oxygen saturations and optical properties. Further validation was performed using in vivo sheep data, where fetal SpO2 values derived from transabdominal continuous-wave near-infrared spectroscopy measurements were compared against reference fetal SaO2 from CO-oximetry. In simulations, the algorithm achieved a mean absolute error (MAE) below 5% and a Pearson correlation coefficient (R) of 0.98 between estimated fetal SpO2 and ground truth fetal SaO2 when using optimal input parameters. In the sheep experiment, agreement with reference measurements was maintained (MAE = 10.3%, R = 0.91). However, algorithm performance was highly sensitive to accurate optical properties and tissue layer thicknesses inputs, which may be challenging to obtain in clinical settings. These results demonstrate proof-of-concept feasibility for the multi-layer self-calibrated algorithm in both simulated and in vivo conditions. While further refinement, particularly in optical property estimation and fetal depths in human pregnancies, is necessary, this work provides a foundational framework for the future clinical translation of non-invasive fetal SpO2 monitoring.

Related Concept Videos

Pulse Oximetry01:24

Pulse Oximetry

Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
1.2K
Fetal Circulation01:14

Fetal Circulation

Fetal circulation is a unique system that facilitates the exchange of gases, nutrients, and waste products between the developing fetus and the mother. This intricate process takes place through a special organ called the placenta.
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
2.5K
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
2.3K
Guidelines For Measuring Vital Signs01:19

Guidelines For Measuring Vital Signs

Following these guidelines can help nurses accurately measure vital signs, assess changes in patient conditions, and provide timely treatment when necessary. Adhering closely to the guidelines ensures the accuracy and reliability of the results.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
2.7K