Locally deployed context-aware chatbot outperforms generic large language models for guideline-concordant pediatric
Amit Gupta1, Krithika Rangarajan2, R G Krishna Kumar3
1Room No 48, Department of Diagnostic and Interventional Onco-radiology, Dr BRAIRCH, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India. amit.aiims2014@gmail.com.
Pediatric Radiology
|November 13, 2025
Summary
A new AI chatbot, ped-Llama, provides accurate pediatric imaging recommendations aligned with guidelines. This tool offers expert-level decision support for clinicians, improving care quality.
Area of Science:
- Artificial Intelligence in Medical Imaging
- Clinical Decision Support Systems
- Pediatric Radiology
Background:
- Accurate modality selection in pediatric imaging is crucial but challenging.
- Adherence to American College of Radiology (ACR) Appropriateness Criteria is often limited.
- Large language models (LLMs) show promise for decision support but require domain-specific accuracy.
Purpose of the Study:
- To assess the performance of a locally run, context-aware chatbot (ped-Llama) for pediatric imaging recommendations.
- To evaluate its accuracy against ACR guidelines and compare it with other LLMs and human experts.
- To determine the utility of retrieval-augmented generation (RAG) in enhancing LLM performance for medical applications.
Main Methods:
- A simulation study used 50 pediatric clinical scenarios based on ACR guideline variants.
- The ped-Llama chatbot, utilizing a RAG approach with Llama-3.1-8B, was compared to generic LLMs (Llama-3.1-8B, GPT-4o, Claude Opus) and radiologists.
- Recommendations were classified using ACR criteria, and LLM output consistency was analyzed.
Main Results:
- ped-Llama achieved 80% "Usually appropriate" recommendations, surpassing generic LLMs and matching specialist radiologist performance.
- Including "May be appropriate" recommendations, ped-Llama reached 90% accuracy.
- ped-Llama demonstrated higher consistency (72%) across multiple runs compared to generic LLMs (44-50%).
Conclusions:
- A locally run, RAG-enabled chatbot using an open-source LLM can deliver guideline-concordant pediatric imaging recommendations with expert-level accuracy.
- This demonstrates the potential of AI-assisted decision support systems in radiology.
- Such systems offer a practical and scalable solution for improving clinical decision-making in pediatric imaging.
Related Concept Videos
Improving Translational Accuracy
14.0K
Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...