Related Experiment Video
Updated: May 3, 2026

Author Spotlight: Establishing an Accurate Microhardness Testing Protocol for Craniofacial Tissues
Published on: April 26, 2024
Effect of Chlorhexidine Solution on the Tensile Bond Strength and Hardness of Two Soft Liners With Denture Base
Deepak Kumar Samal1, Tapan K Patro1, Angurbala Dhal1
1Prosthodontics, Crown and Bridge, Srirama Chandra Bhanja (SCB) Dental College and Hospital, Cuttack, IND.
Abstract:
Background Edentulism presents significant functional, nutritional, and psychological challenges, often requiring complete denture rehabilitation. Soft denture liners are used to enhance comfort and fit, and functionality of existing dentures, especially in patients with compromised oral tissues. However, the longevity of their performance is hindered by the deterioration of tensile bond strength and material softness. Chlorhexidine gluconate solution, recommended as a denture cleanser, may alter these properties. Objective To evaluate the effect of 0.2% chlorhexidine gluconate solution (HEXIDINE -ICPA Health Products Ltd, Mumbai, India) on the tensile bond strength and Shore A hardness values of two types of denture liners: acrylic-based, Permasoft (Perma Laboratories, Broadview Heights, OH, USA), and silicone-based Ufi Gel P (VOCO GmbH, Cuxhaven, Germany), bonded to heat-cured polymethyl methacrylate (PMMA) denture base resin (AcryPol R, Ruthinium, Dental Manufacturing S.P.A., Badia Polesine, Italy). This study investigated whether the daily use of chlorhexidine solution alters the mechanical properties of these commonly used denture liners. Materials and methods Seventy-eight specimens were prepared to assess the effect of 0.2% chlorhexidine gluconate on the tensile bond strength and Shore A hardness of two soft denture liners: acrylic-based, Permasoft, and silicone-based, Ufi Gel P, bonded to heat-cured PMMA resin. For tensile strength testing, fifty-two specimens were fabricated by bonding two PMMA blocks (40 × 10 × 10 mm) with a 3 mm thick liner. For hardness testing, twenty-six cylindrical specimens (6 mm height, 10 mm diameter) were prepared. Specimens were divided into two groups for immersion in distilled water as a control and in 0.2% chlorhexidine gluconate solution. Tensile bond strength was measured using a universal testing machine. Failure modes were classified as adhesive, cohesive, or mixed. Hardness was evaluated using a Shore A digital durometer, with five readings per specimen. Results Permasoft exhibited significantly higher tensile bond strength (mean: 0.72 MPa) compared to Ufi Gel P (mean: 0.60 MPa). Shore A hardness values were also greater for Permasoft (mean: 45.5) than Ufi Gel P (mean: 36.1). Specimens immersed in distilled water showed higher tensile bond strength than those treated with 0.2% chlorhexidine gluconate (P = 0.001). Conversely, Shore A hardness increased following chlorhexidine immersion for both liners, with Permasoft reaching the highest value (49.3). Two-way analysis of variance (ANOVA) revealed significant main effects of material type and solution on both tensile bond strength and hardness (P = 0.001). Conclusions Both Permasoft and Ufi Gel P demonstrated clinically acceptable tensile bond strength with PMMA denture base resin. However, daily immersion in 0.2% chlorhexidine gluconate solution significantly reduced tensile bond strength and increased Shore A hardness in both materials compared to distilled water. Ufi Gel P showed better compatibility with chlorhexidine solution than Permasoft, under disinfectant exposure. While chemical denture cleansers are effective for oral hygiene, their impact on material properties should be carefully considered in clinical practice.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:02Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Related Concept Videos
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with...
Chemical Bonds
Atoms participate in a chemical bond formation to acquire a completed valence-shell electron configuration similar to that of the noble gas nearest to it in atomic number. Ionic, covalent, and metallic bonds are some of the important types of chemical bonds. Bond energy and bond length determine the strength of a chemical bond.
Types of Chemical Bonds
An ionic bond is formed due to electrostatic attraction between cations and anions. Often, the ions are formed by the transfer of electrons...
Strain and Elastic Modulus
Physical Properties of Carboxylic Acid Derivatives
Among the carboxylic acid derivatives, the boiling points of acid chlorides and esters are very similar and are the lowest in the series. Acid anhydrides have slightly higher boiling...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Toughness and Hardness of Aggregate