Mechanical Performance of Two NiTi Rotary Files: Effects of Alloy and Design of Fatigue, Torsion, Bending, and
José Aranguren1, Gema Galvan2, Carmen Bonilla3
1Department of Endodontics, Rey Juan Carlos University, Madrid, Spain.
Abstract:
This study evaluated the mechanical performance of nickel-titanium (NiTi) endodontic instruments with identical tip diameters but different alloy compositions and designs. The study compared two geometric configurations of WaveOne Gold instruments (Respectively, WO I and WO II) manufactured using three different NiTi alloys: SE-Wire (non-heat-treated superelastic NiTi), M-Wire, and gold alloy. WO I instruments have a variable taper (25/0.08) and dual convex triangular cross-section, while WO II instruments feature a reduced taper (25/0.07), square cross-section, and shorter handle. Six groups were tested for cyclic fatigue resistance, torsional strength, bending behavior, deformation, and compressive load. Fracture patterns were examined via scanning electron microscopy (SEM). A two-way ANOVA evaluated interactions between alloy type and instrument design. Alloy heat treatment and design significantly affected performance. Gold alloy instruments showed superior flexibility and the highest time-to-fracture (TTF) values, particularly in WO II. WO II files required less pressure to navigate canals and demonstrated better bending adaptability due to their reduced taper and square cross-section. In contrast, SE-Wire instruments had the lowest fatigue resistance and highest pressure loads, indicating their austenitic phase and lack of thermal treatment. WO I instruments had higher torsional strength but fractured at lower angular deflections. SEM revealed distinct fracture mechanisms based on alloy and generation. WO II instruments outperformed WO I in flexibility, cyclic fatigue resistance, and canal tracking, particularly with thermomechanically treated alloys like Gold. The relationship between alloy composition and instrument design is crucial for optimizing performance and minimizing procedural risks.
Related Concept Videos
Fatigue
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...
Stress Concentrations in Circular Shafts
Torsion of Noncircular Members
Thin-Walled Hollow Shafts
Plastic Deformation in Circular Shafts