Comparing Clinical Outcomes of Various Presbyopia-Correcting Intraocular Lenses Using a Novel Composite Method for
Mateja Jagić1, Maja Bohač2, Alma Bišćević3
1School of Medicine, University Eye Hospital Svjetlost, University of Rijeka, Heinzelova 39, 10000, Zagreb, Croatia. mateja.jagic@svjetlost.hr.
Introduction:
This work aims to monitor the stability of composite descriptors of uncorrected distance (UCDVA), intermediate (UCIVA), and near (UCNVA) logMAR acuities after uneventful phacoemulsification and presbyopia correcting intra-ocular lenses (PCIOLs) implantation.
Methods:
Patients implanted with AcrySof IQ PanOptix (group 1, n = 32), TECNIS Symfony (group 2, n = 35), TECNIS bifocal (group 3, n = 34), or TECNIS monofocal (comparative, group 4, n = 32) were followed up for 12 months. In each case, the errors in the composite descriptor of [I] UCDVA and UCNVA doublets (EDN = √[(UCDVA)2 + (UCNVA)2]) and [II] UCDVA, UCIVA and UCNVA triplets (EDIN = √[(UCDVA)2 + (UCIVA)2 + (UCNVA)2]) were monitored for targeted postoperative uncorrected logMAR acuities of zero. EDN and EDIN values were subjected to 2D and 3D graphical treatments to identify the absolute changes (ΔEDN and ΔEDIN) occurring between 1 week and 1 month, 1 and 6 months, and 6 and 12 months.
Results:
There were small changes in residual refractive errors, UCDVA, UCIVA, UCNVA, EDN, EDIN, ΔEDN, and ΔEDIN values within, or between, groups 1-3. In groups 1 to 4, respectively. (i) Between 1 week and 1 month postop, the mean (± SD, 95% CI) ΔEDN values were 0.03 (± 0.05, 0.01-0.05), 0.05 (± 0.08, 0.02-0.08), 0.04 (± 0.07, 0.02-0.06), 0.19 (± 0.14, 0.14-0.24) and the ΔEDIN values were 0.04 (± 0.06, 0.01-0.05), 0.06 (± 0.10, 0.03-0.09), 0.04 (± 0.08, 0.01-0.07), 0.23 (± 0.14, 0.18-0.28). Differences were significant (one-way ANOVA for ΔEDN, F = 20.65, p < 0.001; for ΔEDIN, F = 25.03, p < 0.001), but not after excluding group 4. (ii) Between 6 and 12 months, postop ΔEDIN values > 0.1 logMAR occurred in 3 (10%), 6 (17%), 4 (12%), and 1 (3%) of cases.
Conclusions:
The changes in uncorrected distance, intermediate, and near visual acuities were small and remained relatively stable 1 week following implantation with PCIOLs. Fewer than 20% of cases experienced a change in composite description of acuities > 0.1 logMAR between 6 and 12 months postop.
Trial Registration:
ClinicalTrials.gov identifier: NCT07008768.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
06:19Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...