Related Experiment Video
Updated: Jan 11, 2026

Author Spotlight: Standardization and Best Practices for Advancing Lung Imaging Using 129Xe MRI
Published on: November 21, 2023
Comparing Mean-anchored Generalized Linear Binning with Established Methods to Quantify Xenon-129 Ventilation Defect
Riaz Hussain1, Abdullah S Bdaiwi1, Joseph W Plummer2
1Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH (R.H., A.S.B., J.W.P., B.I.M., M.M.W., L.L.W., Z.I.C.).
Rationale And Objectives:
Hyperpolarized xenon-129 (129Xe) MRI is an established, sensitive method to assess ventilation but lacks a standardized ventilation defect quantification. We introduce mean-anchored generalized linear binning (MeanGLB, GLB) to calculate ventilation defect percentage (VDP), benchmarking its performance against reader-segmented VDP (Reader) and five widely-used automated VDP calculation methods.
Materials And Methods:
129Xe images were acquired from 38 people with cystic fibrosis (CF) and 25 age-matched healthy controls (HCs) using 2D-spiral sequence. Flexible chest coil-induced inhomogeneities were mitigated using both N4- or a flip-angle (FA)-based bias correction. VDP was quantified using Reader, Hierarchical and Adaptive K-means clustering, mean-normalized linear binning, 99th Percentile-normalized GLB, binary Thresholding, and MeanGLB; and compared for all techniques. Additionally, VDPs obtained via automated methods were evaluated against Reader. Voxel-wise agreement with Reader-based defect maps was assessed using sensitivity, specificity and Youden's index.
Results:
Using N4-corrected images, all methods-except Hierarchical-showed significant difference in VDP between participants with CF and HCs (P<0.05). For FA-corrected images, similar significance was observed for all methods (P<0.05), except Hierarchical and Adaptive. While MeanGLB overestimated defects in participants with CF, for both N4- and FA-corrected images (Bland-Altman biases: -3.1% and -1.9%, respectively), it strongly correlated with Reader (r=0.97, P<0.001 both). MeanGLB achieved the highest Youden's index (∼0.75) across N4- and FA-corrected images, indicating balance of sensitivity and specificity.
Conclusion:
MeanGLB enabled robust quantification of VDP in 129Xe ventilation MRI, independent of bias-correction algorithm. Its ability to capture subtle impairments indicates its potential for applications in pulmonary imaging.