Related Experiment Video
Updated: Jan 11, 2026

09:08
Author Spotlight: Standardization and Best Practices for Advancing Lung Imaging Using 129Xe MRI
Published on: November 21, 2023
1.3K
Comparing Mean-anchored Generalized Linear Binning with Established Methods to Quantify Xenon-129 Ventilation Defect
Riaz Hussain1, Abdullah S Bdaiwi1, Joseph W Plummer2
1Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH (R.H., A.S.B., J.W.P., B.I.M., M.M.W., L.L.W., Z.I.C.).
Academic Radiology
|November 15, 2025
Summary
A new method, Mean-anchored generalized linear binning (MeanGLB), robustly quantifies ventilation defect percentage (VDP) in hyperpolarized xenon-129 MRI. This technique shows potential for detecting subtle pulmonary impairments in patients with cystic fibrosis.
Area of Science:
- Medical Imaging
- Pulmonary Medicine
- Quantitative MRI
Background:
- Hyperpolarized xenon-129 (129Xe) MRI is a sensitive tool for assessing lung ventilation.
- Standardized quantification of ventilation defects remains a challenge in 129Xe MRI.
Purpose of the Study:
- To introduce and evaluate Mean-anchored generalized linear binning (MeanGLB) for calculating ventilation defect percentage (VDP).
- To benchmark MeanGLB against reader-segmented VDP and other automated methods.
Main Methods:
- 129Xe MRI data from 38 cystic fibrosis patients and 25 healthy controls were analyzed.
- Ventilation defect percentage (VDP) was quantified using MeanGLB, reader-segmented analysis, and five other automated methods.
- Bias correction was performed using N4 or flip-angle (FA) methods; voxel-wise agreement was assessed using sensitivity, specificity, and Youden's index.
Main Results:
- MeanGLB demonstrated significant differences in VDP between cystic fibrosis patients and controls, regardless of bias correction method.
- MeanGLB showed strong correlation with reader-segmented VDP (r=0.97) and achieved the highest Youden's index (∼0.75).
- While MeanGLB slightly overestimated defects in cystic fibrosis patients, it proved robust across different bias correction techniques.
Conclusions:
- MeanGLB provides a robust and reliable method for VDP quantification in 129Xe ventilation MRI.
- The method is independent of the bias-correction algorithm used.
- MeanGLB's sensitivity to subtle impairments suggests its utility in pulmonary imaging applications.