Validation and enhancement of two predictive models evaluating physiological strain during physical work while
Giorgos K Gkikas1, Giorgos Papangelis1, Konstantinos Mantzios1
1FAME Laboratory, Department of Physical Education and Sport Science, University of Thessaly, Greece.
None:
The prediction of physiological strain is essential for the safety of personnel in high-risk environments especially when wearing personal protective equipment (PPE). This study aimed to develop a usability-enhanced variant of the Heat Strain Decision Aid (HSDA), named HSDA-FL (FAME Lab), by implementing automatic workload estimations, alternative environmental inputs, and a revised initialization delay logic. The second aim was to evaluate whether these modifications preserved the original model's validity. The third aim was to evaluate the performance of HSDA, HSDA-FL, and the PHS-FL models while wearing chemical, biological, radiological, and nuclear (CBRN) PPE. Eleven acclimatized participants completed a 40-min simulated CBRN reconnaissance scenario involving walking and inspection tasks. The HSDA-FL was tested with both the original and the revised delay logic, demonstrated significantly lower residual errors than the original HSDA (p<0.001), with the revised delay logic variant achieving the highest accuracy (MAE=0.151°C, RMSE=0.191°C, bias=0.011°C). In contrast, the PHS-FL performed significantly worse than all HSDA-based models (p<0.001). These findings confirm that HSDA-FL maintains and slightly exceeds the predictive validity of the original HSDA while improving usability, whereas PHS-FL was not deemed sufficiently reliable for use with CBRN clothing.
Related Concept Videos
Personal Protective Equipment
Clearance Models: Physiological Models
The organ's clearance rate depends on the blood flow to the organ and the extraction ratio (E). The extraction ratio describes the organ's...
Model Approaches for Pharmacokinetic Data: Physiological Models
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.