Related Experiment Video
Updated: May 10, 2026

Optical Trapping of Nanoparticles
Published on: January 15, 2013
Non-linear bistability in pulsed optical traps
Alex J Vernon1, Francisco J Rodríguez-Fotuño1, Anatoly V Zayats1
1Department of Physics and London Centre for Nanotechnology, King's College London, Strand, London, WC2R 2LS, UK.
None:
Optical trapping, also known as optical tweezing or optical levitation, is a technique that uses highly focused laser beams to manipulate micro- and nanoscopic particles. In optical traps driven by high-energy pulses, material non-linearity can result in unusual opto-mechanical effects, such as displaced equilibrium points. However, existing theoretical models of non-linear optical force on small particles consider smooth material dependence on the incident field strength alone, and not the feedback between the particle permittivity and internal field strength, which is, in turn, a function of the permittivity. The hysteresis effects of optical bistability in pulsed optical traps, therefore, elude existing optical force models. Here, we investigate a bistable optical trap, set up by counter-propagating ultrashort pulses, in which the optical force exerted on a particle depends not only on the field at its current location but on the historic trajectory of the particle in the trap. The developed formalism will be important for designing optical traps and nanoparticle manipulation in pulsed field for various applications, including potentially time crystal demonstrations.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Confocal Fluorescence Microscopy
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Curvilinear Motion: Normal and Tangential Components
The positive direction of the t-axis aligns with the increasing position of the car along the curved path, denoted by the unit vector ut. Simultaneously, the n-axis, perpendicular to the t-axis, dissects the curved path into differential arc segments, each forming the arc of a circle with a radius of...
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...

