Influence of Topical Fluorescein on Scheimpflug-Based Corneal Densitometry and Potential Applications
Nima Sadeghi1,2, Silke Oellerich1,2, Perseverence Savieri3
1Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel (VUB), Brussels, Belgium.
Topical fluorescein temporarily increases anterior corneal densitometry in healthy eyes, returning to baseline within 20 minutes. This method may objectively detect corneal surface issues like superficial punctate keratitis in dry eye disease patients.
Area of Science:
- Ophthalmology
- Corneal Imaging
- Diagnostic Technologies
Background:
- Corneal densitometry measures light scatter to assess corneal tissue.
- Scheimpflug imaging is a non-invasive technique for corneal analysis.
- Dry eye disease (DED) can cause superficial punctate keratitis (SPK), impacting corneal surface integrity.
Purpose of the Study:
- To evaluate how topical fluorescein affects Scheimpflug-based corneal densitometry.
- To determine the optimal timing for reliable corneal densitometry imaging after fluorescein instillation.
- To assess fluorescein-enhanced densitometry's potential for detecting SPK in DED patients.
Main Methods:
- Twenty healthy participants underwent Scheimpflug imaging at various time points after fluorescein instillation.
- Corneal densitometry was measured in different corneal layers and zones.
- Reproducibility was assessed, and one DED patient with SPK was examined.
Main Results:
- Fluorescein significantly increased anterior corneal densitometry, peaking at 5 minutes and returning near baseline by 20 minutes.
- High reproducibility was observed for measurements taken 10-20 minutes post-instillation.
- In the DED patient, fluorescein-enhanced densitometry identified localized signal elevations corresponding to SPK.
Conclusions:
- Topical fluorescein causes transient, time-dependent changes in anterior corneal densitometry.
- Fluorescein may enhance the detection of epithelial defects, offering an objective method for assessing corneal surface integrity in DED.
- Further research is needed to validate the clinical utility of this technique.