Related Experiment Video
Updated: Jan 11, 2026

15:04
Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
Published on: May 18, 2011
13.5K
Clip-on adapter for simultaneous inline Raman and fluorescence spectroscopy inside semitransparent plastic pipes
L Hirschberger1, K Wieland2, M Völkl3
1Chair of Analytical Chemistry and Water Chemistry, School of Natural Sciences, Technical University of Munich, Lichtenbergstrasse 4, 85748, Garching, Germany.
Analytical and Bioanalytical Chemistry
|November 17, 2025
Summary
A novel clip-on adapter enables inline Raman and fluorescence spectroscopy in microflow reactors. This allows real-time monitoring and control of chemical reactions, enhancing process understanding and optimization.
Area of Science:
- Analytical Chemistry
- Chemical Engineering
- Spectroscopy
Background:
- Continuous microflow reactors offer precise control over chemical processes.
- Inline monitoring is crucial for real-time reaction analysis and optimization.
- Standard Raman probes require specialized integration for microflow systems.
Purpose of the Study:
- To develop and present a versatile clip-on adapter for integrating standard Raman probes into microflow reactor systems.
- To enable simultaneous Raman and fluorescence spectroscopy for comprehensive inline chemical analysis.
- To demonstrate the adapter's utility in real-time reaction monitoring and control.
Main Methods:
- A clip-on adapter was designed to fit standard Raman probes (9.5 mm diameter) onto semitransparent tubes (6.35 mm OD).
- The adapter facilitates inline spectroscopic measurements in reflection (Raman) and 90° (fluorescence) modes.
- Simultaneous Raman and fluorescence spectroscopy were applied to analyze vegetable oil mixtures and monitor esterification reactions.
Main Results:
- The adapter allows flexible positioning on fixed or flexible tubing for adaptable inline measurements.
- Demonstrated simultaneous Raman and fluorescence detection for analyzing complex mixtures like vegetable oils.
- Investigated the impact of integration time and flow rate on signal intensity for olive oil analysis.
- Successfully applied non-contact inline Raman monitoring for acid-catalytic esterification of ethyl acetate.
Conclusions:
- The developed clip-on adapter provides a simple and effective solution for inline spectroscopic analysis in microflow reactors.
- Simultaneous Raman and fluorescence spectroscopy offer enhanced capabilities for real-time process monitoring and control.
- This technology facilitates improved understanding and optimization of chemical reactions in continuous flow systems.