Stress distribution and axial force under different filing parameters during root canal preparation: An in vitro FEA
Dianhao Wu1, Zhixian Qiu2, Yanshuang Bai2
1Department of Mechanical Engineering and Automation, University of Science and Technology Liaoning, Anshan, Liaoning Province, 114051, People's Republic of China.
Background:
Inappropriate rotational and feed speed of the rotary nickel-titanium (Ni-Ti) file can cause damage to the root canal wall. Consequently, it is essential to examine the relationships among filing parameters, file stress, and axial force to establish a dependable foundation for the selection of parameters.
Method:
A 3D reconstruction of the tooth is executed utilizing CBCT images. The reaming rate of root canal filling is established at 30 % to examine the correlation between Root Canal Preparation (RCP) parameters and damage under critical situations. Utilizing the elastic-plastic model and the Johnson-Cook intrinsic model, the explicit dynamics method of ABAQUS software is employed to simulate the contact stress and axial force at varying feed speeds (1-8 mm/s) and rotational speeds (150-800 rpm). A robotic arm-based filing experimental platform is developed to conduct bionic experiments, which examine the variation of axial filing force with different parameters, and these results are compared with simulation outcomes.
Results:
Increased rotational speed and decreased feed speed of the root canal file can diminish the stress and strain on the root canal. The trends and magnitudes of axial force derived from simulation and experiment at varying speeds are comparable (deviation factor = 0.15 %-25.82 %). A rotational speed higher than 350 rpm and a feed speed lower than 6 mm/s are more conducive to stable and safe filing, and the maximum axial force and the maximum stress exhibit a trend analogous.
Conclusion:
This study provides a basis for the selection of filing parameters for manual and robot-assisted RCP, thereby improving the safety of clinical preparation.
More Related Videos
03:07Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
11:28A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
Related Concept Videos
Normal Strain under Axial Loading
Stress Concentrations in Circular Shafts
Stress on an Oblique Plane
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....