Empirical phenotyping of joint patient-care data supports hypothesis-driven investigation of mechanical ventilation
J N Stroh1,2, Peter D Sottile3, Yanran Wang4
1Department of Biomedical Informatics, University of Colorado Anschutz, Aurora, CO, 80045, USA. jn.stroh@cuanschutz.edu.
Abstract:
Analyzing patient data under current mechanical ventilation (MV) management processes is essential to understand MV consequences over time and to hypothesize improvements to care. However, progress is complicated by the complexity of lung-ventilator system (LVS) interactions, patient-care and patient-ventilator heterogeneity, and a lack of classification schemes for observable behavior. Ventilator waveform data originate from patient-ventilator interactions within the LVS while care processes manage both patients and ventilator settings. This study develops a computational pipeline to segment joint waveform and care settings timeseries data into phenotypes of the data generating process. The modular framework supports many methodological choices for representing waveform data and unsupervised clustering. The pipeline is generalizable although empirical output is data- and algorithm-dependent. Applied individually to 35 ARDS patients including 8 with COVID-19, a median of 8 phenotypes capture 97% of data using naive similarity assumptions on waveform and MV settings data. Individual's phenotypes organize around ventilator mode, PEEP, and tidal volume with additional delineation of waveform behaviors. However, dynamics are not solely driven by setting changes. Fewer than 10% of phenotype changes link to ventilator settings directly. Evaluation of phenotype heterogeneity reveals LVS dynamics that cannot be discretized into sub-phenotypes without additional data or alternate assumptions. Individual phenotypes may also be aggregated for use in scalable analysis, as behaviors in the 35 patient cohort comprise 16 cohort-scale LVS types. Further, output phenotypes compactly discretize the data for longitudinal analysis and may be optimized to resolve features of interest for specific applications.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: