Characterization of a simple potentiometric graphite based sensor and its effective applicability in sensitive and
Menna A Gaber1, Gehad G Mohamed1,2, M M Omar1
1Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt.
Abstract:
The importance of Cu(II) in environmental, biological, and industrial systems makes it crucial to develop a highly selective and sensitive analytical methodology for its determination. Herein, a graphitic based sensor modified with a Schiff base, namely 2-(((3-aminophenyl) imino) methyl) phenol was developed and applied. A broad concentration range (1 × 10-7- 1 × 10-1) mol L-1 was covered by the electrode's linear response to Cu(II), which had a 29.571 ± 0.8 mV decade-1 Nernstian slope. It was highly reproducible (inter and intraday RSDs%=0.94-2.12), with a response time of approximately 15 s and pH working rang was from 3.5 to 6.5. and had a two-month lifespan. With this modified sensor, 5.0 × 10-8 mol L-1 was the detection limit and1.65 × 10-7 mol L-1 was the limit of quantification. Over a wide range of metal ions, the suggested electrode exhibited very good selectivity for Cu(II) applying separate solution method(SSM), fixed interference method (FIM) and matched potential method (MPM). Cu(II) levels in Several samples like spiked water samples, Hairvogine multivitamin and Nutrifol vegetable foliar were accurately determined potentiometrically by either direct, or standard addition methods using this chemically altered carbon paste electrode giving a comparable results with atomic absorption spectroscopy (AAS) technique. Scanning electron microscope (SEM) combined with energy dispersive X-ray (EDX) were utilized for morphological analysis of sensors' reactive surface combined with elemental analysis as well.
More Related Videos
12:03Two-Dimensional Visualization and Quantification of Labile, Inorganic Plant Nutrients and Contaminants in Soil
Published on: September 1, 2020
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
Related Concept Videos
Precipitation and Co-precipitation
Potentiometric Titration: Overview
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Extraction: Advanced Methods